background image

BG300 Barrier Gate 

User Manual 

P a g e

 | 

2  

 

 Copyright©2022 ZKTECO CO., LTD.  All rights reserved. 

ZKTeco  does  not  assume  responsibility  for  any  errors  or  omissions  in  the  information  or 

documents which are referenced by or linked to this manual. The entire risk as to the results 

and performance obtained from using the information is assumed by the user. 

ZKTeco  in  no  event  shall  be  liable  to  the  user  or  any  third  party  for  any  incidental, 

consequential, indirect, special, or exemplary damages, including, without limitation, loss of 

business, loss of profits, business interruption, loss of business information or any pecuniary 

loss, arising out of, in connection with, or relating to the use of the information contained in 

or  referenced  by  this  manual,  even  if  ZKTeco  has  been  advised  of  the  possibility  of  such 

damages.  

This  manual  and  the  information  contained  therein  may  include  technical,  other 

inaccuracies  or  typographical  errors.  ZKTeco  periodically  changes  the  information  herein 

which will be incorporated into new additions/amendments to the manual. ZKTeco reserves 

the  right  to  add,  delete,  amend,  or  modify  the  information  contained  in  the  manual  from 

time to time in the form of circulars, letters, notes, etc. for better operation and safety of the 

machine/unit/equipment.  The  said  additions  or  amendments  are  meant  for  improvement 

/better operations of the machine/unit/equipment and such amendments shall not give any 

right to claim any compensation or damages under any circumstances. 

ZKTeco shall in no way be responsible (i) in case the machine/unit/equipment malfunctions 

due  to  any  non-compliance  of  the  instructions  contained  in  this  manual  (ii)  in  case  of 

operation of the machine/unit/equipment beyond the rate limits (iii) in case of operation of 

the  machine  and  equipment  in  conditions  different  from  the  prescribed  conditions  of  the 

manual. 

The  product  will  be  updated  from  time  to  time  without  prior  notice.  The  latest  operation 

procedures and relevant documents are available on 

http://www.zkteco.in.

 

If there is any issue related to the product, please contact us. 

ZKTeco Biometric India Pvt Ltd. 

Address

 

B-1, Khata No.31, Devasandra Industrial Estate,  

Whitefield Main Road, Beside Phoenix Mall, 

 

               

 Mahadevapura, Bengaluru, Karnataka. 

Phone 

080 8628 1342 

For business-related queries, please write to us a

[email protected].

 

To know more about our global branches, visit 

www.zkteco.in.

 

 

 

Содержание BG300

Страница 1: ...ing our product Please read the instructions carefully before operation Follow these instructions to ensure that the product is functioning properly The images shown in this manual are for illustrativ...

Страница 2: ...ent s of the manual seems unclear or incomplete please contact ZKTeco before starting the operation and maintenance of the said equipment It is an essential pre requisite for the satisfactory operatio...

Страница 3: ...e amend or modify the information contained in the manual from time to time in the form of circulars letters notes etc for better operation and safety of the machine unit equipment The said additions...

Страница 4: ...development of biometric verification procedures and the productization of biometric verification SDK which was initially widely applied in PC security and identity authentication fields With the con...

Страница 5: ...and field names are inside square brackets For example pop up the New User window Multi level menus are separated by forwarding slashes For example File Create Folder Symbols Convention Description T...

Страница 6: ...BOOM INSTALLATION PROCEDURE 12 6 LEFT AND RIGHT DIRECTIONS 13 7 MAINBOARD WIRING INSTRUCTIONS 13 CONNECTION WITH LPR CAMERA 14 CONNECTION WITH UHF CONTROLLER 14 CONNECTION WITH LOOP DETECTOR 15 CONNEC...

Страница 7: ...r Manual P a g e 6 Copyright 2022 ZKTECO CO LTD All rights reserved 9 COMMISSIONING INSTRUCTIONS 23 10 PRODUCT PACKING LIST 24 11 TROUBLESHOOTING 25 12 SAFETY PRECAUTIONS 27 13 TRANSPORTATION AND STOR...

Страница 8: ...g time 2 Features and Functionalities 1 The fastest operating speed is 1 5s the speed can be adjusted according to different boom arm length 2 Digital control monitoring support delay automatic close...

Страница 9: ...BG300 Barrier Gate User Manual P a g e 8 Copyright 2022 ZKTECO CO LTD All rights reserved 3 Appearance and Dimensions...

Страница 10: ...g Speed 1 5 6s Boom Length Max 6m Boom Type Telescopic straight boom Chassis Dimensions 1010 350 280mm Weight 43KG Motor Type 24V DC brushless motor Output Power 160W Output Current 10A Working Voltag...

Страница 11: ...ut it cannot be increased After the boom has been cut it is important to set the spring balance again to achieve a new balance The bottom of the spring contains two plastic nuts designed to adjust the...

Страница 12: ...BG300 Barrier Gate User Manual P a g e 1 1 Copyright 2022 ZKTECO CO LTD All rights reserved Dimensions...

Страница 13: ...wered on to run the test process be sure to install the barrier boom of the corresponding length for the test If the barrier boom is not installed please adjust and remove the spring under the guidanc...

Страница 14: ...ard Wiring Instructions 1 Please disconnect the power supply before wiring 2 To switch the input voltage to 110V please note that you need to set the DIP switch as shown in the below image 3 Check car...

Страница 15: ...Copyright 2022 ZKTECO CO LTD All rights reserved BG300 Wiring Diagram of Mainboard Connection with LPR Camera Connection with UHF Controller Note The Reader1 and 2 of Inbio260 Controller corresponds t...

Страница 16: ...arrier Gate User Manual P a g e 1 5 Copyright 2022 ZKTECO CO LTD All rights reserved Connection with Loop Detector Anti smash and Auto close function BG300 Barrier Gate Mainboard BG300 Barrier Gate Ma...

Страница 17: ...rights reserved Coil Circumference Coil Number 3m Based on requirements ensure that the inductance is 3m to 6m 5 to 6 turns 6m to 10m 4 to 5 turns 10m to 25m 3 turns 25m 2 turns Connection with VR10 R...

Страница 18: ...BG300 Barrier Gate User Manual P a g e 1 7 Copyright 2022 ZKTECO CO LTD All rights reserved Connection with Infrared Photocell Detector Anti smash function BG300 Barrier Gate Mainboard...

Страница 19: ...BG300 Barrier Gate User Manual P a g e 1 8 Copyright 2022 ZKTECO CO LTD All rights reserved Anti smash and Auto close function...

Страница 20: ...trokes Mainboard Parameter Settings Key Description Menu Menu options Confirm and Enter Enter Confirm and Exit Open Decrease parameter value Close Increase parameter value 8 1 1 Operating Procedure Th...

Страница 21: ...ti smashing Car Response Time Sensitivity Adjustment The shorter the reaction time the higher the sensitivity L 4 30 30 30 Motor Strength Adjustment Default L 5 70 70 70 Horizontal Boom Barrier Adjust...

Страница 22: ...rning State 253 Automatic deletion of the remote control L F 0 0 0 Deceleration stroke adjustment for the first section of the opening gate Default L H 0 0 0 Deceleration stroke adjustment of the seco...

Страница 23: ...ring Long press Menu then press to select L F L15 Press Menu again to set the parameter value and then set the parameter value to 253 At this time it will automatically return to the menu indicating t...

Страница 24: ...ctor and public interface the falling boom is transferred to rising immediately which will stop automatically after the rising limit 4 In the process of boom falling short connect the loop detector an...

Страница 25: ...e spring and the boom length type matching 10 Product Packing List Material Quantity Chassis Explosion Screw M12X140 4 Keys 2 Barrier Boom 1 Boom Pressure Plate 1 Chassis Pressure Plate 2 Wireless Rem...

Страница 26: ...2 Replace the mainboard 3 Tighten the wiring 2 Problem The AC input is normal but the power indicator is off Cause 1 The power fuse might be blown 2 Abnormal power supply 3 Loose wiring Solution 1 Rep...

Страница 27: ...he same frequency 3 There may be obstacles nearby 4 The remote control frequency is not matched or the receiver is damaged Solution 1 Replace the battery 2 Use manual button control 3 Use in open area...

Страница 28: ...portation and Storage While loading and unloading the product please handle with care During transportation and storage place the product in a dry and corrosive free environment The product should be...

Страница 29: ...1 Khata No 31 Devasandra Industrial Estate Whitefield Main Road Beside Phoenix Mall Mahadevapura Bengaluru Karnataka Phone 080 6828 1342 www zkteco in Copyright 2022 ZKTECO CO LTD All Rights Reserved...