BG300 Barrier Gate
User Manual
P a g e
|
2 2
Copyright©2022 ZKTECO CO., LTD. All rights reserved.
Remote Control Pairing and Unpairing
1.
Remote Control Pairing: Long press Menu, then press +/- to select L-F [L15]. Press Menu
again to set the parameter value. At this time, the LED display value is "000", and then
press any button on the remote control until you hear a beep sound from the Mainboard.
If it automatically returns to the menu option, it means the pairing is successful, and then
press Enter to exit the menu.
2.
Delete Remote Control Pairing: Long press Menu, then press +/- to select L-F [L15].
Press Menu again to set the parameter value, and then set the parameter value to "253".
At this time, it will automatically return to the menu, indicating that all the remote
controls have been deleted.
Set Delay for Automatic Closing after Opening the Boom
Long press the Menu button, then press +/- to select the L20 parameter, and then press the
Menu to set the parameter value after selection. At this time, 000 will be displayed on the
screen which means that the device is in the disabled state. Set the delay value as per the
requirements. Finally, press Enter to exit the menu. For example, if it is set to "005", the
machine will automatically close after 5 seconds after opening the barrier.