Compatibility 

This section lists the products compatible with your addressable fire system 
when using the 900 Series protocol. 

Note: 

Compatible products may change without notice. Always contact your local 

supplier to confirm availability and compatibility. 

Caution: 

Products marked with an asterisk (*) are not suitable for installation in 

fire systems requiring EN 54-13 compliance. 

Mounting bases for addressable devices 

 

Model 

Type 

MFG code 

Description 

DB950 

N/A 

45681-210 

950/990 Series mounting base 

DB950B 

N/A 

45681-361 

950/990 Series mounting base black 

DB950EZ 

N/A 

45681-250 

950 Series E-Z fit mounting base 

DB950R 

N/A 

45681-242 

950 Series low power relay base 

DB951 

N/A 

45681-211 

IU950/IU955 intelligent loop isolator base 

DB961 

N/A 

45681-284 

950 Series mounting base with isolator 

DB970* 

N/A 

45681-215 

970 Series IS detector base 

 

Addressable manual call points 

 

Model 

Type 

MFG code 

Description 

DM950BI-D* 

MCPx 

245663 

950 Series blue manual call point with 
isolator (aluminum) 

DM950I-D 

MCPx 

245739 

950 Series red manual call point with 
isolator (aluminium) 

DM980FI-N 

MCPd 

B30120 

980 Series red manual call point with 
isolator – “feuerwehr” (plastic) 

DM980I-N 

MCPd 

B30110 

980 Series red manual call point with 
isolator – EN 54-11 (plastic) 

DMN960I 

MCPx 

55100-908 

950 Series red manual call point - red with 
back box and glass 

DMN960IE 

MCPd 

58100-951 

990 Series red manual call point with 
isolator (surface mount, waterproof) 

DM961* 

MCPx 

 

950 Series yellow manual call point with 
back box and glass 

DMN960G* 

MCPd 

58100-929 

990 Series green manual call point with 
back box and resettable element 

DM980BI-N* 

MCPd 

B30130 

980 Series blue manual call point with 
isolator – “hausalarm" (plastic) 

DM970 

MCPx 

55100-940 

950 Series red IS manual call point (no 
flap) 

 

www.acornfiresecurity.com

www.acornfiresecurity.com

Содержание ZP2 Series

Страница 1: ...900 Series Protocol Guide for ZP2 Series Control Panels www acornfiresecurity com www acornfiresecurity com...

Страница 2: ...n 1 Intended audience and purpose 1 Firmware compatibility 1 Installation 2 Registering the 2010 2 PAK 900 2 Connecting loop devices 3 Configuration 4 Detector configuration 4 Sounder configuration 5...

Страница 3: ...ts essential purpose Installation in accordance with this manual applicable codes and the instructions of the authority having jurisdiction is mandatory While every precaution has been taken during th...

Страница 4: ...ormation on topics not specific to the 900 Series protocol see your control panel installation and operation manuals Firmware compatibility Information in this document covers control panels with firm...

Страница 5: ...s to confirm the registration 5 Press Apply to apply the registration details to the panel or Continue to register more PAKs for the same control panel To apply the 900 Series protocol 1 Remove the PA...

Страница 6: ...l and then press the jog dial to confirm the selection 4 When the update is complete remove the jumper from JP4 and then press Reboot to restart the control panel The control panel is now configured t...

Страница 7: ...sponding loop and device The loop device configuration menu displays 3 Select Base and then select YES to enable the detector base 4 Press F4 Enter and then press F1 Back 5 Press F1 Save F3 Apply F4 D...

Страница 8: ...ld setup from the Main menu and then select Loop device config 2 Select the corresponding loop and device The loop device configuration menu displays 3 Select act_grp and then assign the required grou...

Страница 9: ...magnetic wand to locally test each of the loop sounders 3 When you have finished press the jog dial again to exit loop walk test mode 4 Press F1 Back or F2 Exit Adjusting the volume Select Snd volume...

Страница 10: ...ration 1 Select Field setup from the Main menu and then select Loop device config 2 Select the corresponding loop and device The loop device configuration menu displays 3 Select and check Radio to ena...

Страница 11: ...N A 45681 215 970 Series IS detector base Addressable manual call points Model Type MFG code Description DM950BI D MCPx 245663 950 Series blue manual call point with isolator aluminum DM950I D MCPx 2...

Страница 12: ...escription II950I SIMx 55000 760 950 Series mini switch monitor with isolator II952D SIMx 55000 822 950 Series switch monitor with DIN rail mount II952I SIMx 55000 843 950 Series switch monitor with i...

Страница 13: ...NEN SDx 55000 276 950 Series 100 dB loop powered standalone sounder slow whoop AS967I SDx 55000 005 950 Series intelligent loop powered open area red sounder beacon with isolator AS967WRCI SDx 55000 0...

Страница 14: ...D detectors Wireless devices Model Type MFG code Description II955IRF ZMx XPA IN 14007 APO Xpander zone monitor unit with isolator DT934RF HDx XPA CB 11170 APO Xpander A1R heat detector DT937RF HDx XP...

Страница 15: ...55000 440 970 Series addressable IS heat detector DB970 N A 45681 215 970 Series IS detector base GBX70 N A 29600 098 950 Series IS galvanic barrier PT971 N A 55000 855 970 Series IS 1 channel protoc...

Отзывы: