ZIPPER MASCHINEN GmbH www.Zipper-Maschinen.at
25
ZI-STE6700DH & ZI-STE7500DSH
14.1.2
Transport / Storage
In order to avoid the generator leaking oil during transport or temporary storage, make sure to
switch off the generator, keeping it at a standing pose under normal operations. After the engine is
totally cooled, turn the ventilating pole of the fuel-
filling lid to the “OFF” position thoroughly.
When transporting the generator:
Do not let the fuel spill out of the fuel tank. (The top of the fuel-filling tank should have no fuel.)
When the generator is placed on a vehicle, do not run the engine. You should take the generator
down from the car before operation.
When you take the generator to the car, avoid exposing it to sunshine. If it is put in sealed
carriage for a long time, the high temperature of the carriage may cause the fuel to boiling
away, thus leads to burn.
Before the generator is put into a long-time storage, you should:
Make sure the storage area is clean and dry.
N O T I C E
Store the machine with closed inlet- and outlet valves. Therefore, pull on the rope of
the starter until you fell resistance.
14.2
Disposal
Do not dispose of the machine in residual waste. Contact your local authorities for
information regarding the available disposal options. When you buy at your local
dealer for a replacement unit, the latter is obliged to exchange your old.StromPLAN /
Wiring-Diagram
15
TROUBLESHOOTING
Disconnect the machine from the power supply prior to any checks
performed at the machine itself!
Trouble
Reason
Shooting
Engine will not start
up
Fuel cock closed
No fuel
Too little oil in the tank
Air in fuel pipeline
Battery too weak
Set fuel cock in
position “ON”
Refill fuel
Refill oil
Have the fuel pipeline blown through
Charge the battery with appropriate
charger
Engine runs
unevenly
Wrong fuel
Air in fuel pipeline
Use correct fuel
Have the fuel pipeline blown through
Motor too little
power
Dirty air filter
Clean the filter elements, possibly
exchange
Low output voltage
under load
Too much load available
Reduce existing load
Uneven Output
voltage
Unbalanced load available
Disconnect all electrical consumers.
Then apply again individually to
determine which consumer causes
the uneven loads.
High noise level
Loose screw connections
Tighten all screws
N O T I C E
Should you in necessary repairs not able to properly to perform or you have
not the prescribed training for it always attract a workshop to fix the problem.