ASSEMBLY
12.1
Delivery content
Please check the product contents immediately after receipt for any eventual transport damage or
missing parts. Claims from transport damage or missing parts must be placed immediately after
initial machine receipt and unpacking before putting the machine into operation. Please understand
that later claims cannot be accepted anymore.
12.2
Workplace requirements
The workplace has to fulfill the requirements.
The ground has to be even, in level and hard. It must be suitable at least to weight it with double
weight per square meter than the machines net weight.
The chosen workplace must have access to a suitable electric supply net hat complies with the
machines requirements.
12.3
Transportation
Only use the handle on the motor housing for maneuvering the machine.
12.4
Power supply
W A R N I N G
Dangerous electrical voltage!
The connection of the machine as well as electrical inspections, maintenance and repair
may only be carried out by qualified personnel or under guidance and supervision of a
qualified electrician!
The connection of the machine to the electric power supply and the following checks have to be
carried out by a respectively trained electrician only.
1.
The electronic connection of the machine is designated for operation with a grounded power
socket!
2.
The connector plug may not be manipulated.
3.
The grounding wire should be held in green-yellow.
4.
The mains supply must be secured with 10A.
5.
Check that the mains voltage complies with the requirements of the machine.
6.
In case of repair or replacement, the grounding conductor must not be connected to a live
box!
7.
Make sure that a possible extension cord is in good condition and suitable for the
transmission of power. An undersized cord reduces the transmission of power and heats up.
8.
A damaged cable must be replaced immediately.
9.
Operation is only allowed with safety switch against stray current (RCD max. stray current
of 30mA).
N O T I C E
Use only permitted extension cable with cross-section the one in the
following table declared.
Voltage
Extension
Cross-section
220 V-240 V
50 Hz
<27 m
1,5 mm
2
<44 m
2,5 mm
2
<70 m
4,0 mm
2
<105 m
6,0 mm
2