CEX-O_CEX-U, Maintenance and User Instructions V1.02
Page 4
March / 2014
Model
CEX-O
CEX-U
Application
Over-sink
Under-sink
Nominal supply voltage
1/N/PE 230V~
Power Rating (kW)
6.6 / 8.8
(1)
Rated Current (A)
29 (6.6kW) / 38 (8.8kW)
Element type
Bare wire
Rated pressure
1 MPa (10 bar)
Temperature adjustment range
30
o
C - 55
o
C
Maximum inlet temperature
70
o
C
Factory set flow rate at 3 bar (l/min)
4.2
Minimum flow rate (l/min)
2.0
Maximum flow rate (l/min)
5.0
Flow rate @ 38
o
C (l/min)
(2)
3.6 (6.6kW) / 4.8 (8.8kW)
Flow rate @ 50
o
C (l/min)
(2)
2.5 (6.6kW) / 3.3 (8.8kW)
Pressure loss @ 2.5 l/min
0.2 bar
@ 9.0 l/min
1.3 bar
(3)
Required specific water resistance @ 15
o
C
>1100 ohm.cm
Dimensions H x W x D (mm)
294 x 177 x 108
Maximum weight (kg)
2.7
Rated volume (litres)
0.3
Water connections (BSP)
1/2”
Protection class
IP25
IP24
(1)
Power rating selected at time of installation.
(2)
At 12
o
C incoming water temperature.
(3)
Without flow regulator
All data quoted at nominal supply voltage . Standard European voltage tolerances of -6%
to +10% may be applied.
A minimum water presure of 0.2 MPa (2 bar) is recommended for optimum
performance.
Maximum flow rate will be achieved at a water pressure of 0.6 MPa (6 bar).
The appliance must not be subject to more than 1 MPa (10 bar).