Reinstallation
If the appliance is to be re-commissioned
under different installation conditions it may be
necessary to alter the maximum power rating.
This should only be done by a competent
installer.
To re-set the maximum power rating use a
screwdriver to short circuit the two pins as
shown in Fig.8.
This will reset all heaterparameters to factory
settings.
Value “88” will flash in the display panel until
the maximum power rating has been selected.
Lock level
Operation of the appliance can be restricted.
Refer to instructions under “Service Menu” to
set the lock level.
This should only be done by a competent
installer.
Activation of the Lock level:
1. Set the required lock level in the service
menu (refer to instructions under “Service
Menu”).
2. Disconnect the power supply to the unit.
3. Move the jumper on the main PCB from pin
2 to pin 1 (see Fig 9).
4. Reconnect the power supply to the unit.
Deactivation of the Lock level:
1. Disconnect the power supply to the unit.
2. Move the jumper on the main PCB from pin
1 to pin 2.
3. Reconnect the power supply to the unit.
Fig. 8
Fig. 9
7. Open the hot water tap and check the appliance is functioning correctly.
8. Explain operation of the appliance to the end user and leave the operating
instructions for their reference.
9. Complete the product registration card and return it to Zip Heaters or register the
product on line at www.zipheaters.co.uk