March / 2014
Page 3
CEX-O_CEX-U_Installation, Maintenance and User Instructions V1.02
•
Children should be supervised in order to make sure that they do not play with the appliance.
•
CAUTION
•
Optimum operation is ensured at a water flow pressure of 0.2 to 0.4 MPa (2-4 bar). The
appliance must not be subjected to pressure exceeding 1.0 MPa (10 bar).
•
The appliance must only be used when correctly installed and in perfect working order.
•
The appliance must be installed in a frost-free room and must never be exposed to frost
•
The CEX-0 and CEX-U range is not intended for use with thermostatic mixing valves or taps.
•
The appliance must be completely filled with water before being switched on.
•
Before commissioning for the first time and each time the appliance is emptied (e.g. due to
work on the plumbing system or maintenance), the appliance must be vented by opening
and closing the hot water tap until all air has been eliminated from the water heater and no
more air emerges before re-connecting to the electrical supply.
•
The appliance must only be used for heating potable water. The specific water resistance
must not fall below the required value indicated on the rating plate. The appliance must not
be used for any other purpose.
•
Incoming water temperature must not exceed 70°C.
•
The Zip InLine is intended for mains supply only. In any other case please contact Zip on
0845 6 005 005 for advice.
•
Zip Heaters (UK) Ltd cannot be held liable for any damages caused by failure to
observe these instructions.
Содержание InLine CEX-O
Страница 2: ......