CEX-O_CEX-U_Installation, Maintenance and User Instructions V1.02

Description

Zip InLine CEX-O and CEX-U instantaneous water heaters are micro-processor controlled, 
pressure resistant water heaters suitable for supplying hot water to one or more outlets.
The heating element switches on automatically when the hot water tap is opened and 
switches off automatically when the hot water tap is closed.
The electronic control system automatically regulates the power consumption  depending on 

the supply water temperature and flow rate to achieve the required outlet temperature within 

the power limit of the appliance.
Power consumption is also regulated based on outlet temperature to ensure the required 

temperature is achieved exactly to the degree and irrespective of fluctuations in voltage 

and water pressure.
The power rating of the appliance can be selected as either 8.8kW or 6.6kW at 230V at the 
time of installation.
The required outlet temperature can be entered on a keypad within the range 30°C to 55°C 
and can be read off the digital display.
The maximum inlet temperature of 70°C is suitable for use with preheated water e.g. from 
solar heating systems.

Approvals

Zip InLine CEX-O and CEX-U are VDE approved to the LVD and EMC directives and are CE 
endorsed.
Zip InLine CEX-O and CEX-U have been examined, tested and found when correctly fitted 
to comply with the requirements of the United Kingdom Water Regulations / Byelaws 
(Scotland). The products are listed under the WRAS (Water Regulations Advisory Scheme) 
Water Fittings and Materials Directory.

Содержание InLine CEX-O

Страница 1: ...hese instructions carefully before commencing installation of the InLine water heater Please leave these instructions with the end user after installation Zip Heaters UK Ltd 14 Bertie Ward Way Dereham...

Страница 2: ......

Страница 3: ...the latest copy In order to preserve our environment we ask that you dispose of this product correctly Please contact Zip Customer Service for advice on 0845 6 005 005 Contents Description 1 Approvals...

Страница 4: ...mperature to ensure the required temperature is achieved exactly to the degree and irrespective of fluctuations in voltage and water pressure The power rating of the appliance can be selected as eithe...

Страница 5: ...olate the power supply immediately In case of leaks also isolate the water supply Repairs must only be carried out by Zip Heaters UK Ltd or an authorised Zip service engineer Temperatures in excess of...

Страница 6: ...ith water before being switched on Before commissioning for the first time and each time the appliance is emptied e g due to work on the plumbing system or maintenance the appliance must be vented by...

Страница 7: ...5 6 6kW 3 3 8 8kW Pressure loss 2 5 l min 0 2 bar 9 0 l min 1 3 bar 3 Required specific water resistance 15o C 1100 ohm cm Dimensions H x W x D mm 294 x 177 x 108 Maximum weight kg 2 7 Rated volume l...

Страница 8: ...s specifythe appliance model and serial number IN89589 CEX U IN89588 CEX O Front Cover IN82813 Water Connection IN82512 Temperature Sensor Set IN82810 Heating Element c w STDB IN82802 Inlet Pipe IN828...

Страница 9: ...ensure that the wiring is not directly accessible after installation Check that the power supply is switched off prior to electrical connection Installation site The installation site must be free fro...

Страница 10: ...right marks horizontally B B The intersections of these lines are the drill points see Fig 2 4 Drill the holes using a 6mm drill then insert the dowels and screws provided leaving the screws protrudin...

Страница 11: ...ed wiring is not directly accessible after installation To protect the appliance a circuit breaker must be fitted with a rating suitable for the nominal current of the appliance Check that the power s...

Страница 12: ...Power Rating Selection The maximum power rating of the appliance can be selected as either 8 8kW or 6 6kW at the time of installation The unit will only commence normal operation after selection of t...

Страница 13: ...the lock level This should only be done by a competent installer Activation of the Lock level 1 Set the required lock level in the service menu refer to instructions under Service Menu 2 Disconnect t...

Страница 14: ...gram key 1 to return to the menu item list Press program key 2 to exit the service menu and return to the standard display After two minutes without any key stroke the system automatically returns to...

Страница 15: ...ent LL Lock level The operating mode of the appliance can be restricted Setting options 0 No restriction factory setting 1 Disables Reset to factory setting Parameters can be viewed but not modified i...

Страница 16: ...ature continuously The required outlet temperature can be adjusted between 30 C and 55 C Note reducing the temperature below 30 C displays and the heating function will not operate Program buttons The...

Страница 17: ...and down arrow function keys simultaneously The display will count backwards from 10 to 00 in one second intervals The appliance is reset when the counter reaches 00 Releasing the function keys earlie...

Страница 18: ...brasive cleaners chemicals Clean the casing tapware external filter piping and all other fittings with a soft cloth and mild soap and water Do not spray water over the tap as it may damage the low vol...

Страница 19: ...achieved MAX lights up Excessive water flow rate Reduce water flow rate at the outlet Selected temperature not achieved MAX does not light Cold water has been added at the outlet Set for required tem...

Страница 20: ...r goods furnishings or property Zip does not exclude restrict or modify any liability that cannot be excluded restricted or modified or which cannot except to a limited extent be excluded restricted o...