07
807042 v1.02 08.22 HydroTap G5 UltraCare Install Instructions
SECTION 3: WARNINGS & REGULATORY INFORMATION
•
The Zip HydroTap must be earthed. Earthing is provided via the
supplied power cord. The resistance of the earth connection to each
exposed metal part must be less than 1Ω. Use the power cable supplied.
It is the responsibility of the installer to ensure the power point is
earthed.
• All installation and service work must be completed by trained and
suitably qualified tradespeople. Faulty operation due to unqualified
persons working on this product may void warranty coverage.
• As the installer, it is your responsibility to supply and install all valves as
required by local regulations and relevant standards.
• The HydroTap is rated for 220-240V 50Hz AC operation.
• Use only the power supply provided with the UV-C Module. An
ACM36US21
power supply is provided.
• Do not remove the cover of the appliance under any circumstances
without first isolating the appliance from the power supply.
• Connect only to a potable (wholesome, cat1) mains water supply.
• The new hose sets supplied with the product must be used. Do not
re-use old hose sets.
• Never locate the system near, or clean with water jets.
• Do not expose the Zip HydroTap to the elements of nature.
• The booster complies with protection class IP 20.
• For UK, a pressure limiting valve must be fitted for mains water
• For continued safety of this appliance it must be installed,
operated and maintained in accordance with the
manufacturer’s instructions.
• This appliance may deliver water at high temperature. Refer to
the Plumbing Code of Australia (PCA), local requirements and
installation instructions to determine if additional delivery
temperature control is required.
• The button/coin battery is hazardous and is to be kept away
from children. It can cause severe or fatal injuries in 2 hours
or less if it is swallowed or placed inside any part of the
body. Medical attention should be sought immediately if it
is suspected the battery has been swallowed or placed inside
any part of the body.