36
Quick Start Installation Guide
807042 v1.02 08.22 HydroTap G5 UltraCare Install Instructions
SECTION 13: Commissioning
13.11 Safety sensor calibration
(Classic boiling models only)
Optional, in cases where light recalibration is required.
Pull both levers
forward
Safety
sensor
Light intensity varies from site to site,
therefore it is recommended that a
re-calibration be performed at the time of
the installation. All direct sunlight must
be shaded from the HydroTap, during the
calibration. This can be achieved by closing
any nearby curtains, blinds, etc.
• Shield the HydroTap from direct sunlight.
• In normal operating mode. Turn the
power off.
• Pull both tap levers to the forward
position.
• Turn the power on.
• The safety sensor will calibrate.
• Return the levers to the neutral
position.