805846US v1.04 06.21 HydroTap G4 User Guide
Page 7 of 32
Classic Faucet
Lights
Red lights on:
Boiling water at set temperature
Flashing slowly:
Boiling water below set temp
Flashing quickly:
System fault - refer to LCD screen
Blue lights on:
Chilled water at set temperature
Flashing slowly:
Chilled water above set temp
Flashing quickly:
System fault - refer to LCD screen
All lights flashing:
System fault - refer to LCD screen
Filter light off:
Filter within lifespan
Flashing:
Filter change due (see page 24)
Safety lock sensor RED:
Safety lock active
OFF:
Safety lock is not active
At installation, recalibrate light sensor:
Do not cover
safety lock sensor.
• In normal operating mode and safety enabled, turn the
power OFF.
• Pull both faucet levers to the forward position.
• Turn ON the power. The HydroTap will calibrate the
safety switch. Return the levers to the neutral position.
• To check calibration, dispense boiling water in normal
light conditions, with the safety enabled.