Filter flush should be run at commissioning and whenever the
water filter cartridge is replaced. Have a 10L (3 gallon) bucket or
similar container (not supplied) at the ready to hold a quantity of
water that will be ejected during the Filter Flush process. Open the
filter access door at the front of the HydroTap Command Center
to access the filter cartridge. At the rear RHS of the cartridge is a
flush line and the flush line stop cock.
Once your Zip HydroTap G4 unit has been installed, use the Install
menu to configure:
1 - Filter Flush
Note:
Run at least 10 liters (3
gallons) of water through to
flush the new filter cartridge.
Once the filter flush has
finished, press the Stop
button on the screen.
1. Filter Flush
2. Filter Reset
3. Boiling Calibration
4. Booster
5. CO2 Purge
(sparkling models)
6. Lux Sensor Calibration
7. Advanced options
8. Reset
1. Press [MENU] - [Install] -
[Filter Flush].
2. Place the valve end of the
flush line into the empty
bucket or container, and turn
the stop cock ON.
3. Press [Start] to start filter
flush. Once the filter flush is
finished, turn the stop cock
OFF, then press [Stop] to end
filter flush mode.
4. Press [<=] button for the
previous menu or press
[Home] button to return to
the home screen.
5. Reset the filter counter.
1. Press [Energy] to view Energy
information.
2. Total energy consumption will
be displayed, or
3. Select reset to restart the
energy counter.
4. Press [<=] for the previous
menu or press [Home] to
return to the home screen.