Zip Hydroboil Plus - Installation & Operating Instructions - 82869 - May 2003
Page 7 of 16
Step 5 – Commissioning
Check previous steps. Turn water supply ON, check connections for leaks.
Push tap paddle inwards until water flows, release to stop flow of water.
Turn power ON. After a short period, boiling water will be available and will be
maintained close to boiling point thereafter. Initial heating periods are:
Inlet water temperature
15°C
10°C
3.0 Litre models
16 minutes
17 minutes
5.0 Litre models
16 minutes
17 minutes
7.5 Litre models
23 minutes
24 minutes
Problem Solving
Installation Procedures
continued
Symptom
Possible Cause
Solution
Fails to dispense water.
Water isolating valve turned off.
Blocked filter, blocked meter tube,
blocked strainer, jammed ball valve
assy, airlock in transfer tube.
Check water supply valve.
Contact Zip Service Provider
1800 638633
Water not boiling.
No power.
Faulty pcb, faulty element, faulty
sensor. Incorrectly located sensor.
Check power supply.
Contact Zip Service Provider
1800 638633
Runs out of boiling water and fails to
refill.
Outlet tap drips.
Overflow from vent.
Excessive steam from vent.
Power “on” but no heat.
“Power on”, “Filter active”, “Boiling
water” light on but no heat.
No heat, no”Power on” light.
Overload repeatedly tripping with
excessive steam.
Overload repeatedly tripping without
excessive steam.
No water from ambient button.
Internal adjustment.
Contact Zip Service Provider
1800 638633