Page 10 of 16
Zip Hydroboil Plus- Installation & Operating Instructions - 82869 - May 2003
The Zip Hydroboil timer is set to remind you every 9 months to replace your
filter. When a filter change is due, the Change Filter light will come on and
remain on until reset.
Depending on local water quality conditions and usage, the filter may require
changing every 6 to 12 months. You may also need to replace the filter if you
notice unpleasant odours or tastes, or if the flow rate of the tap is persistently
slow.
Some water may drip from the filter head (socket) and attached water lines
during replacement. Keep a bucket and towel handy to catch drips and mop up
any spills.
1. Locate service valve in the water supply line and turn off the water supply.
2. Grasp filter cartridge and twist right to left one quarter turn until it stops.
3. Ease cartridge downwards to detach it from the filter head (socket).
4. Do not tilt the cartridge as dirty water may spill from it if tilted.
5. Unpack replacement cartridge and write date where shown on the label.
6. Avoid bacterially contaminating cartridge top whilst inserting into head.
7. Align cartridge tabs with the slots on the under-side of the filter head.
8. Slide cartridge upward into head and rotate left to right until it stops.
9. Open the service valve and check filter head for leaks. Refit if leaking.
10. To purge air from filter follow purging procedure described on page 5.
11. Wipe up any spills and dispose of spent filter cartridge and packaging
thoughtfully.
12. Insert wire probe into reset Access Hole on heater fascia to reset the “Filter
Active” light and start filter reminder system timer.
Note:
Freshly installed filters may cause water to appear milky. The water
should clear after running a few litres of water through the filter.
How to Replace the Filter
Filter Head
Filter Cartridge
To remove cartridge,
turn cartridge one
quarter turn right to
left, and draw
downwards.
To replace cartridge
align lugs on filter
cartridge with socket on
filter head. Push
upwards, turn one
quarter turn left to right
until secure
Reset Access Hole