Warning: this appliance must be earthed.

Following remedial service the earthing continuity of the heater must be
checked by a qualified technician using an appliance tester, or continuity tester
of accuracy Class 5 or better. Class 5 denotes an accuracy of 5% full scale
deflection.

1. Isolate power supply.

2. Set meter to 0 ohm with leads connected together.

3. Connect one test lead to the earth pin on the three pin plug.

4. Connect the other test lead to a bare patch of metal (preferably on the edge)
of the top of the cover, then to the front cover of the unit, and then to the tap
top under the plastic paddle. This can be achieved by inserting the probe up
from behind the paddle without losing water.

Warning-

the water may be boiling - show extra care.

5. Test that in every instance the electrical resistance does not exceed 1 ohm.

Tap Operation

Boiling water

Zip Hydroboil Plus is fitted with a two-way cool-touch safety tap for filtered
instant boiling water.

For filtered instant boiling water, gently press the lower end of the tap paddle
inwards.

Boiling water will flow until the tap paddle is released.

This operation gives fingertip flow control for safe filling of cups and mugs.

For filtered instant boiling water to fill larger vessels such as teapots and
saucepans, lift the tap paddle until it locks into a horizontal position.

Boiling water will flow until the paddle is returned to its normal vertical
position. This operation allows the vessel to be filled without holding your hand
where it may be affected by steam.

Drinking water

Zip Hydroboil Plus is also fitted with a chrome plated push button tap for
filtered drinking water.

For filtered drinking water, press the push button inwards. Filtered ambient
temperature water will flow until the button is released.

Filtered water dispensed by the Zip Hydroboil should be stored chilled as the
process of filtration removes chlorine from the water supply.

Earthing Continuity Verification

TESTER
CONNECT BETWEEN THE
EARTH ON THE THREE PIN
PLUG OR EARTH CABLE
AND EXPOSED METAL
PARTS AS PER POINT 4 AT
RIGHT

Operating Procedures

 

Содержание Hydroboil Plu series

Страница 1: ...Litre with Sub Micron Triple Action Filter Zip Hydroboil Plus 7 5 Litre with Sub Micron Triple Action Filter Zip Hydroboil Plus 3 Litre with Five Micron Triple Action Filter Zip Hydroboil Plus 5 Litre...

Страница 2: ...ation 5 c Venting 5c Venting 6 d Electrical 6 Step 4 Assembling 6 Wall mounting Template and Electrical Diagrams 6 Installation Procedures Continued 7 Srep 5 Commissioning 7 Problem Solving 7 Earthing...

Страница 3: ...res above sea level the installer should contact Zip for high altitude settings This appliance must be earthed If the power supply cord is damaged it must be replaced by a Zip Service Provider or a qu...

Страница 4: ...ll holes where shown Drill holes for water inlet vent outlet and wiring if rear access is intended Remove cover fastening screws from heater and lift whole cover off heater Detach both nozzles from ba...

Страница 5: ...r inch tube from the sink drain For superior appearance fix a chrome plated tube between the sink top and heater underside as a conduit for the flexible tube Trim the quarter inch tube supplied to con...

Страница 6: ...contact seperation of at least 3 mm in all poles Step 4 Assembling Place the heater case back on to the heater and secure the top 2 case screws Place outlet nozzles on nozzle fascias at base of the he...

Страница 7: ...Possible Cause Solution Fails to dispense water Water isolating valve turned off Blocked filter blocked meter tube blocked strainer jammed ball valve assy airlock in transfer tube Check water supply...

Страница 8: ...ool touch safety tap for filtered instant boiling water For filtered instant boiling water gently press the lower end of the tap paddle inwards Boiling water will flow until the tap paddle is released...

Страница 9: ...ted the filter is operating within the pre set filter life span At the end of the pre set filter life span period the Filter Active illumination is turned off and the text Change Filter is illuminated...

Страница 10: ...ay spill from it if tilted 5 Unpack replacement cartridge and write date where shown on the label 6 Avoid bacterially contaminating cartridge top whilst inserting into head 7 Align cartridge tabs with...

Страница 11: ...9 Months SW2 Filter change 6 Months SW2 Filter change 12 Months The cut off temperature and differential switch SW1 and the filter timer switch SW2 have a factory presetting as follows SW1 cut off tem...

Страница 12: ...3 Pass N A Not applicable PERFORMANCE SPECIFICATION Zip Five Star Water Filter Model 28005 Sub Micron Triple Action for Boiling Water The filter cartridge has been designed to perform to the followin...

Страница 13: ...ll reduce tastes and odours 3 V Chemical Treatment Will decrease chlorine compounds 3 This appliance may increase the bacterial content of water unless supplementary treatment is provided Legend 3 Pas...

Страница 14: ...t Hydroboil 2000B 10 90574 Fascia lens kit 2000B coated 11 90561 PCB Lights kit 12 90594 Main PCB kit for HB s 13 90127 Overload kit Hydroboil 2000B 14 90560 Tap Handle Kit Coated 15 90562 Outlet Nozz...

Страница 15: ...Zip Hydroboil Plus Installation Operating Instructions 82869 May 2003 Page 15 of 16 Spare Parts 1 2 4 3 5 7 8 9 16 17 18 19 22 23 25 26 10 21 20 15 14 13 11 12 24 6 25 26...

Страница 16: ...e or consequential damage to any other goods furnishings or property No warranty applies to the life of any filtration cartridge installed with the appliance as cartridge life may vary according to wa...

Отзывы: