The recommended optional

 

Water block is ideal for limiting potential  

leakage and resulting water damage from water chillers and their  

supply pipe work, which are subject to mains water pressure. 

It is easily installed via standard 3/4” BSP water connection and can be pre-

set from 5 to 50 litres. The Water block also incorporates a  

non-return valve.

HE45004

Water block

General installation instructions 

Push fit fittings

 

Precautions

The plumbing installation must be undertaken in accordance with local water authority 
regulations and these Installation instructions.

As the installer, it is your responsibility to supply (if necessary) and install all valves as 
required by local regulations and relevant standards.

The chiller and filtration systems are indoor units and must not be exposed to the 
elements.

Take care, when bending rigid plastic tubing, to prevent it from kinking or crushing 
around a bend. The plastic tubing contains water under mains pressure, be careful not 
to nick, scratch or damage it during installation.  
Cut the tube squarely with a sharp knife or tube cutter. Shake out and remove any 
swarf and debris before connection. 

Ensure there is adequate ventilation available through the chiller space. If there is 
inadequate ventilation, and the chiller space temperature rises to above 40°C, the 
chiller may become damaged and malfunction, which will void the product warranty.

For both CT2/140 and DOMCT1 there must be a minimum 168 cm

2

 of cross-flow 

ventilation. Suitable holes or vents will need to be cut into the cupboard and door.

If the incoming mains cold water supply pressure exceeds 0.7 MPa (7.0 bar) a 
pressure reducing valve is required to be fitted in the supply line. (See Spare parts and 
accessories page 3).

Electrical

Electrical connection must be made by a Zip service engineer or a qualified electrician. 
(See Safety information, page 2).

This appliance must be earthed.
DO NOT

 turn the electricity supply on until the system is purged. (See Filter 

replacement page 8).

Refer to the configuration diagram page 6.

Содержание ChillTap Extra CT2/140

Страница 1: ...T1 Installation operating instructions June 2015 v1 01 Installation and operating instructions Zip ChillTap Extra Filtered Ambient and Chilled drinking water appliances for work and home Affix model number label here ChillTap Extra ...

Страница 2: ...pliances must be wired to a double pole switched fused spur with a minimum breaking capacity of 13 amps and protected by a suitably rated RCD Installation must comply with current IEE regulations and any local authority requirements This appliance must be earthed Check that the power supply is switched off prior to electrical connection The product its wiring and piping must not be modified in any...

Страница 3: ... order to make sure that they do not play with the appliance The appliance must only be used when correctly functioning and installed Chilled water appliances are approved to the LVD and EMC directives and CE marked This product has been examined tested and found when correctly fitted to comply with the requirements of the United Kingdom Water Regulations Byelaws Scotland The products are listed u...

Страница 4: ...kinking or crushing around a bend The plastic tubing contains water under mains pressure be careful not to nick scratch or damage it during installation Cut the tube squarely with a sharp knife or tube cutter Shake out and remove any swarf and debris before connection Ensure there is adequate ventilation available through the chiller space If there is inadequate ventilation and the chiller space t...

Страница 5: ...bly to the incoming water supply line Note Before assembling the compression fitting to the valve apply sufficient PTFE tape to the thread to ensure a water tight connection Do not turn the water on until the complete system has been connected and purged see Filter replacement page 8 Installing the tap ChillTap Extra Install the ChillTap Extra in a position where there is a Ø52mm wide flat area wi...

Страница 6: ...nnect the white tube supplied in the tap kit between the INLET connection on the filter head marked with arrow pointing towards the filter head to the pressure limiting multifunction valve Trim to length before fitting Use the 4off pipe clamps and 4off 1 2 self tap screws provided to secure tubes appropriately to prevent applying stress to pipe connections ChillTap Extra Outlet Inlet Chiller unit ...

Страница 7: ...the left forward to the horizontal position When finished dispensing water both levers automatically return to the OFF vertical position once finger pressure has been removed Commissioning Secure all pipes and cables After the system is correctly installed and connected turn the incoming mains cold water supply on Check all connections for leaks Repair as necessary again turn the incoming mains co...

Страница 8: ...the under sink cupboard Grasp the filter cartridge firmly and twist it horizontally a quarter turn clockwise until it stops Some water will drip from the filter head during the replacement process so it is a good idea to have a bucket and towel handy to catch and mop up any spills Gently ease the cartridge downwards to detach it from the filter head then pull it out and discard responsibly Take ca...

Страница 9: ...t to permit free flow of air through the vents They should be checked regularly at least monthly and dusted or vacuumed Service There are no user serviceable parts but there are dangerous voltages present within the under counter chiller unit All service work must only be carried out by a suitably qualified and experienced trades person Before calling for service check that both the water and elec...

Страница 10: ...ominated by Zip No costs are payable by the customer other than any mileage or travelling time charges incurred by a Zip Service Provider or the cost of removal cartage and re installation of any component of the appliance if it needs to be returned for repair to Zip or its Distributor This warranty does not cover damage resulting from non operation of the appliance the use of non authorised parts...

Страница 11: ...Page 11 of 12 Zip CT2 140 DOMCT1 Installation operating instructions June 2015 v1 01 Notes ...

Страница 12: ...folk NR19 1TE www zipheaters co uk Telephone 0845 6 005 005 0345 6 005 005 Fax 01362 692448 Web www zipheaters co uk e mail info zipheaters co uk Registering Your Purchase Registering your Zip installation on the Zip website may help to establish date of installation should it become necessary to service the appliance under terms of the Zip warranty ...

Отзывы: