Zip ChillTap Extra CT2/140 Скачать руководство пользователя страница 10

Page 10 of 12 

Zip CT2/140, DOMCT1- Installation & operating instructions - June 2015 v1.01

In order to help preserve our environment we ask that you dispose of this 
product correctly. Please contact your local council for collection centre details.

End of life disposal

The use of this crossed out wheeled bin logo indicates that this product needs to be disposed of separately 
to any other household waste.

Within each of the European Union member countries, provisions have been made for the collection and 
recycling of unwanted electrical and electronic equipment.

In order to preserve our environment we ask that you dispose of this product correctly.  
Please contact Zip customer service for advice on 0845 6 005 005, 0345 6 005 005.

Warranty information

Certain warranties may be implied by law into your contract with Zip. The warranty 
provided below is additional to these implied warranties and nothing set out below 
shall limit your statutory rights or rights at law. 

Zip Heaters UK Ltd warrants that, should any part fail within 12 calendar months of 
installation, that part will be repaired or replaced free of charge by Zip or its Distributor 
or Service Provider, except as set out below, provided the appliance is installed and 
used strictly in accordance with the instructions supplied, and that failure is not due to 
accident, misuse, abuse, unsuitable water conditions, or to any alteration, modification 
or repair by any party not  expressly nominated by Zip. 

No costs are payable by the customer other than any mileage or travelling-time 
charges incurred by a Zip Service Provider or the cost of removal, cartage and 
re-installation of any component of the appliance if it needs to be returned for repair to 
Zip or its Distributor. 

This warranty does not cover damage resulting from non-operation of the appliance, 
the use of non-authorised parts or consequential damage to any other goods, 
furnishings or property.

No warranty applies to the life of any filtration cartridge installed with the appliance as 
cartridge life may vary according to water quality and the rate of water consumption.  

Zip does not exclude, restrict or modify any liability that cannot be excluded, restricted 
or modified or which cannot, except to a limited extent, be excluded, restricted or 
modified as between the owner or user and Zip under the laws applicable. 

Furthermore, this warranty does not displace any statutory warranty, but, to the extent 
to which Zip is entitled to do so, the liability of Zip under any statutory warranty will 
be limited at Zip’s option to the replacement of the appliance or supply of equivalent 
appliance, the payment of the cost of replacing the appliance or acquiring an 
equivalent appliance, or the payment of the cost of having the appliance repaired or 
the repair of the appliance.

Registering Your Purchase

Registering your Zip installation on the Zip website may help to establish date of 
installation should it become necessary to service the appliance under terms of the Zip 
warranty. To register your installation go to www.zipheaters.co.uk and look under the 
heading “Warranty”

.

Содержание ChillTap Extra CT2/140

Страница 1: ...T1 Installation operating instructions June 2015 v1 01 Installation and operating instructions Zip ChillTap Extra Filtered Ambient and Chilled drinking water appliances for work and home Affix model number label here ChillTap Extra ...

Страница 2: ...pliances must be wired to a double pole switched fused spur with a minimum breaking capacity of 13 amps and protected by a suitably rated RCD Installation must comply with current IEE regulations and any local authority requirements This appliance must be earthed Check that the power supply is switched off prior to electrical connection The product its wiring and piping must not be modified in any...

Страница 3: ... order to make sure that they do not play with the appliance The appliance must only be used when correctly functioning and installed Chilled water appliances are approved to the LVD and EMC directives and CE marked This product has been examined tested and found when correctly fitted to comply with the requirements of the United Kingdom Water Regulations Byelaws Scotland The products are listed u...

Страница 4: ...kinking or crushing around a bend The plastic tubing contains water under mains pressure be careful not to nick scratch or damage it during installation Cut the tube squarely with a sharp knife or tube cutter Shake out and remove any swarf and debris before connection Ensure there is adequate ventilation available through the chiller space If there is inadequate ventilation and the chiller space t...

Страница 5: ...bly to the incoming water supply line Note Before assembling the compression fitting to the valve apply sufficient PTFE tape to the thread to ensure a water tight connection Do not turn the water on until the complete system has been connected and purged see Filter replacement page 8 Installing the tap ChillTap Extra Install the ChillTap Extra in a position where there is a Ø52mm wide flat area wi...

Страница 6: ...nnect the white tube supplied in the tap kit between the INLET connection on the filter head marked with arrow pointing towards the filter head to the pressure limiting multifunction valve Trim to length before fitting Use the 4off pipe clamps and 4off 1 2 self tap screws provided to secure tubes appropriately to prevent applying stress to pipe connections ChillTap Extra Outlet Inlet Chiller unit ...

Страница 7: ...the left forward to the horizontal position When finished dispensing water both levers automatically return to the OFF vertical position once finger pressure has been removed Commissioning Secure all pipes and cables After the system is correctly installed and connected turn the incoming mains cold water supply on Check all connections for leaks Repair as necessary again turn the incoming mains co...

Страница 8: ...the under sink cupboard Grasp the filter cartridge firmly and twist it horizontally a quarter turn clockwise until it stops Some water will drip from the filter head during the replacement process so it is a good idea to have a bucket and towel handy to catch and mop up any spills Gently ease the cartridge downwards to detach it from the filter head then pull it out and discard responsibly Take ca...

Страница 9: ...t to permit free flow of air through the vents They should be checked regularly at least monthly and dusted or vacuumed Service There are no user serviceable parts but there are dangerous voltages present within the under counter chiller unit All service work must only be carried out by a suitably qualified and experienced trades person Before calling for service check that both the water and elec...

Страница 10: ...ominated by Zip No costs are payable by the customer other than any mileage or travelling time charges incurred by a Zip Service Provider or the cost of removal cartage and re installation of any component of the appliance if it needs to be returned for repair to Zip or its Distributor This warranty does not cover damage resulting from non operation of the appliance the use of non authorised parts...

Страница 11: ...Page 11 of 12 Zip CT2 140 DOMCT1 Installation operating instructions June 2015 v1 01 Notes ...

Страница 12: ...folk NR19 1TE www zipheaters co uk Telephone 0845 6 005 005 0345 6 005 005 Fax 01362 692448 Web www zipheaters co uk e mail info zipheaters co uk Registering Your Purchase Registering your Zip installation on the Zip website may help to establish date of installation should it become necessary to service the appliance under terms of the Zip warranty ...