804052US v1.27 06.21 CS75 Install Instructions 

Page 7 of 28

Important Safety Instructions

WARNINGS

1.  The Zip HydroTap Command Center must be earthed. The resistance of the 

earth connection from each exposed metal part must be less than 1 ohm.

2.  All Installation and service work must be completed by trained and suitably 

qualified Tradespeople. Faulty operation due to unqualified persons working 

on this product, or any other Zip product may void warranty coverage.

3.  All Plumbing and Electrical connections must comply with local, state and 

federal codes.

4.  All Plumbing and Electrical connections must be made in accordance with 

local regulations.

5.  Ensure the electrical power supply at the installation site is suitable for 

your HydroTap. HydroTap models are rated for either 110-120V, 60Hz, OR 

230V, 50Hz AC installations.

6.  Command Centers must never be located near, or cleaned with water jets.
7.  Zip HydroTaps are not to be exposed to the elements of nature
8.  Due to the process of continuous improvement, Zip reserves the right to 

change details mentioned in this manual, without notice.

9.  If this device is not maintained and operated as specified in this document, 

there is a risk of exposure to contaminants.

!

CO

2

 Cylinder Warnings:

• 

Pressurised container.

• 

Protect from sunlight.

• 

Contains gas under pressure, may explode if heated.

• 

Do not expose to temperatures exceeding 50°C (122°F).

• 

Do not pierce or burn, even after use. 

• 

Do not refill – non rechargeable

• 

Ensure cylinder is empty before disposal.

• 

Do not expose to naked flame or any incandescent material.

• 

Keep out of reach of children.

• 

High concentration of gas may cause asphyxiation.

• 

Use only in ventilated areas.

• 

Store in a location with a volume no less than 50 cubic meters for each 6 lb 

bottle.

• 

Use only in an upright position.

• 

This bottle must be used with the approved pressure regulator.

• 

Avoid shock.

• 

Use according to MSDS (Material Safety Data Sheet).

Содержание CS 75

Страница 1: ...804052US v1 27 06 21 CS75 Install Instructions Page 1 of 28 CS 75 Zip HydroTap Installation and Operating Instructions Scan QR Code to download the latest version of this document English French...

Страница 2: ...customer s needs For ease of installation it is recommended to fit the faucet before installing the Command Center The installation procedure for each of the faucets is detailed in the Faucet Installa...

Страница 3: ...for All Models 11 2 2 Cabinet Air Circulation 12 STEP 3 Fit the CO2 Gas cylinder Section 3 CO2 Cylinder and regulator 3 1 Secure the cylinder mounting 14 3 2 Connect the regulator 14 3 3 Connect the...

Страница 4: ...appliance rating plate and ensure correct power is available for the appliance G Check the under counter cabinet supporting the appliance is adequate for the total weight of the appliance when full of...

Страница 5: ...the chilled water Chilled water dispensed is factory set to 6 10 C 43 50 F These units are NOT designed to be used for sanitary fixtures The CO2 bottle and the water filter require periodic replacemen...

Страница 6: ...cian Qualifications If the power cable is damaged it must be repaired only by a qualified technician To avoid hazards all Installation procedures must be carried out by a suitably qualified tradespers...

Страница 7: ...ver be located near or cleaned with water jets 7 Zip HydroTaps are not to be exposed to the elements of nature 8 Due to the process of continuous improvement Zip reserves the right to change details m...

Страница 8: ...on hose Vent Kit 1x Inlet vent 1x Outlet vent 9 x Screws 1x Installation Instructions this book and 1x User Guide 1x CO2 gas cylinder regulator assy Major components and accessories Accessories Descri...

Страница 9: ...faucet CS75 Classic XX CS75 ARC XX and CS75 CUBE XX have been tested and certified by WQA against NSF ANSI Standard 372 for low lead requirement and against NSF ANSI Standard 42 and NSF ANSI Stand ar...

Страница 10: ...oses and positioned so that the connection point and the stop cock will not be obstructed when the Command Centers are installed A cold water supply with a working pressure range of 250 700 kPa 37 100...

Страница 11: ...and a 12mm Drill Keyhole or Wall Board saw 2 1 Ventilation for All Models Proper air circulation must be provided for all models The system will operate correctly only if the recommended air gaps are...

Страница 12: ...or higher the inlet vent See Item B below and silicone buffers need to be fitted If the airflow is still insufficient to maintain normal operating temperatures then the inlet vent and door outlet vent...

Страница 13: ...t and door outlet holes as shown 2 Ensure the air inlet vent and air outlet vent are positioned at opposite ends of the same cabinet space 3 Fit the inlet vent as shown and secure with 5 screws 4 If r...

Страница 14: ...the cabinet Make sure the gas bottle can stand before securing to the wall Due to regulatory requirements the gas bottle must be stored securely and in an upright position 3 2 Connect the regulator Ma...

Страница 15: ...h the product Connect the power lead to the HydroTap and connect the plug into the electrical power outlet ensuring both ends are securely engaged to reduce the risk of overheating John Guest fittings...

Страница 16: ...refitting the leaking connection Refit the gas bottle to the hook and loop strap and secure the bottle in an upright position NOTE Care must be taken when working with high pressure carbon dioxide IMP...

Страница 17: ...Sparkling Note Mains hose length is 750mm 30 Plug and Cord length is 1800mm 70 Position the Command Center close to the outlet faucet within reach of the hose and cord lengths supplied Note Note The h...

Страница 18: ...a language After commissioning the system may be customised by selecting further options in Section G Settings within the User Manual 5 1 Select the Language Initial Commissioning screen Language sel...

Страница 19: ...ure 5 After one hour repeat step 2 6 Dispense 2 liters gallon of sparkling water from the sparkling outlet Repeat the 2 liters gallon dispense until the water is clear 7 Check that the water is clear...

Страница 20: ...ckflow of gas and or water out of the internal carbonator In addition to the HydroTap s integral Backflow prevention Some authorities require additional Backflow Prevention to be installed to comply w...

Страница 21: ...ion Call Zip Service Condenser sensor Open Internal fault Check ventilation Call Zip service Compressor driver fault No chilled water Call Zip Service Condenser overtemp Blocked air filter Remove bloc...

Страница 22: ...n or equal to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Red...

Страница 23: ...or equal to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Reduc...

Страница 24: ...or equal to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Reduc...

Страница 25: ...t for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Reduction Requirement Average Reducti...

Страница 26: ...place the Zip Product Determination to repair or replace will be in Zip s sole discretion Repair or replacement services will be at no cost to the Zip Customer provided that a the Zip Product is insta...

Страница 27: ...Servicer Provider who performed the warranty service the purchase date a detailed description of the problem and the address and phone number at which the Zip Customer can be reached Zip is committed...

Страница 28: ...Standard 42 and NSF ANSI Standard 53 This will deliver the required bacteriostatic effect and the reduction of aesthetic chlorine taste odor nominal particulate Class I 0 5 m to 1 m cyst and lead as v...

Отзывы: