Page 16 of 28
804052US v1.27 06.21 CS75 Install Instructions
Installation Instructions
4.3
Test for gas leaks:
Using soapy water perform a leak test. Turn the gas OFF.
Apply the soapy water to the gas connections using a sponge
or brush. Cover all of the gas joints with a liberal amount of
suds.
Turn ON the gas. Inspect the joint for leaks. If any bubbles
appear and grow, there is a gas leak at the connection. The
joint will need to be resealed and tested again. Clean away the
soapy residue and tighten or refit the leaking connection. Make
sure the regulator is turned off when tightening or refitting the
leaking connection.
Refit the gas bottle to the hook-and-loop strap and secure the
bottle in an upright position.
NOTE: Care must be taken when working with high
pressure carbon dioxide.
IMPORTANT:
After replacing a bottle or after making a gas connection,
check for gas leaks between regulator and bottle, and be
-
tween regulator and braided hose.
Test for leaks at these two points
4.4
Installing carbonation valve
1. Connect the white tube for sparkling water from the faucet
to the outlet of the carbonation valve.
2. Connect the white tube from the inlet of the carbonation
valve to the Sparkling Outlet connection on top of the Com-
mand Center, as shown in Section 4.3.
3. See section 5.4 for carbonation valve flow rate adjustment.
To faucet
From Sparkling Outlet
of Command Centre