INSTALLATION AND OPERATING INSTRUCTIONS:
Tool changer, pneumatic, WWR1000 series
Zimmer GmbH
●
Im Salmenkopf 5
●
77866 Rheinau, Germany
●
Phone: +49 7844 9138-0
●
Fax: +49 7844 9138-80
●
www.zimmer-group.de
9
DDOC00291 / 0
EN / 2018-09-1
1
8 Installation of accessories
NOTE:
Observe the separate installation and operating instructions for installing the accessories, especially the
energy elements.
The installation and operating instructions, as well as an overview of accessories, can be found on our
Internet site
www.zimmer-group.de
. If you have further questions regarding accessories, please contact
ZIMMER GmbH customer service at
+49 7844 9138-0.
WARNING:
• Risk of injury in case of unexpected movement of the machine or system into which the element has been
installed.
•
Switch off the energy supply to the machine before all work.
• Secure the machine against being switched on unintentionally.
• Check the machine for any residual energy.
8.1 Installation of inductive proximity switches
The inductive proximity switches
bu
for
sensing the piston position are there to
provide safety. The following operation may
be started only if a clear signal displays the
respective position of the piston. The sensors
are not absolutely necessary for the function
of the element.
Installation of the inductive proximity switch is
done as follows:
►
The inductive proximity switch
bu
must
be inserted into the provided intake
cl
and pushed into the sensor shaft as far as
it will go
After that, clamp the element.
cl
bu