8.3 Loose part presence sensing
►
Insert the inductive proximity switch
dp
in to the provided pilot hole
cu
and position or fix using the
corresponding locknuts
dn
.
Æ
You can find more information
on accessories on our website
www.zimmer-group.de
Æ
The inductive proximity switch
can be installed at two positions
cu
in the fixed part
9
.
►
The bolt
dq
is the dampening
element of the sensor.
9 Emergency release
If the loose part
bp
cannot be disengaged on
an occasion (e.g. crash), it can be manually disengaged at the following points.
9.1 Plug screw (piston resetting)
►
Unscrew and pull out the setscrews
do
completely.
►
Screw the emergency pins
dl
in on
both sides in unison, using the tool.
►
By screwing in the emergency
pins
dl
, the loose part
bp
can be
removed.
9.2 Plug screw (bolt resetting)
►
Unscrew and pull out the setscrews
do
completely.
►
Press the stop bolts
dr
inward using
the tool.
►
By pressing the stop bolts
dr
inward, the loose part
bp
can be
removed.