background image

5

2  Safety notices

CAUTION

Risk of injury and material damage in case of non-compliance

Installation, commissioning, maintenance and repairs may only be performed by qualified specialists in 

accordance with these installation and operating instructions.
The product is state-of-the-art.

It is fitted to industrial machines and is used to hold, transport and store workpieces.

The following are examples of situations in which the product may cause a hazard:
•  The product is not properly installed, used or maintained.
•  The product is not used for its designated purpose.
•  The locally applicable regulations, laws, directives or guidelines are not observed.

 

The product may only be used in accordance with these installation and operating instructions and the 

product's technical data. Any changes or additions to the intended use of the product, as well as modifications 

to the product, such as those in the following examples, require the written permission of the manufacturer:
• 

Use of the product under extreme conditions, such as aggressive fluids or abrasive dusts

•  Additional drilled holes or threads

 

Ö

Zimmer GmbH shall accept no liability for any damage caused by improper use. The operator bears sole 

responsibility.

 

Make sure that the power supply is disconnected before you mount, adjust, modify, maintain or repair the 

product.

 

Whenever work is carried out on the product, make sure that the product cannot be actuated by mistake.

 

Perform maintenance tasks, renovation work or attachment work outside of the machine's danger zone when 

possible.

 

Do not reach into the operational range of the product.

 

Observe the specified maintenance intervals and specifications regarding the quality of the operating material.

 

When using the product under extreme conditions, adjust the maintenance interval according to the degree of 

contamination.

INSTALLATION AND OPERATING INSTRUCTIONS: 

SWM1000

DDOC00964 / a

EN / 2023-01-13

Zimmer GmbH • Im Salmenkopf 5 • 

 77866 Rheinau, Germany • 

 +49 7844 9138 0 • www.zimmer-group.com

Содержание SWM1000 Series

Страница 1: ...INSTALLATION AND OPERATING INSTRUCTIONS Angular pivot unit SWM1000 DDOC00964 THE KNOW HOW FACTORY www zimmer group com...

Страница 2: ......

Страница 3: ...talling the product 10 10 2 Installing the energy supply 10 10 3 Installing accessories 11 10 4 Installing the customer specific application 11 11 Commissioning 12 11 1 Adjusting the swivel angle 12 1...

Страница 4: ...assigned according to the type of danger WARNING This notice warns of a situation that is potentially hazardous to personal health Ignoring these notices can cause serious injury or damage to health Y...

Страница 5: ...the following examples require the written permission of the manufacturer Use of the product under extreme conditions such as aggressive fluids or abrasive dusts Additional drilled holes or threads Z...

Страница 6: ...stood everything Observe country specific accident prevention regulations and the general safety notices The following qualifications are a prerequisite for performing various work on the product 4 1...

Страница 7: ...3 5 3 1 Pneumatic cylinder 2 Joint 3 Stop screw 4 Bearing pin 5 Connecting plate 5 1 Type plate A type plate is attached to the housing of the product XXX XX XXXXXX am an The article number and the co...

Страница 8: ...storage preservation Transport and storage of the product must be done only with the original packaging If the product has already been installed on the superordinate machine unit care must be taken d...

Страница 9: ...he power supply against being switched on unintentionally Check the machine for any residual energy that may be present NOTICE Installation may only be carried out by qualified personnel in accordance...

Страница 10: ...d connections that are available can be found in the accessories list on our website The necessary ordering information can also be found there Use compressed air in accordance with DIN ISO 8573 1 4 4...

Страница 11: ...10 4 Installing the customer specific application Before installation check whether the application is suitable in terms of weight Position the application on the product with the straight pins Insta...

Страница 12: ...our website for information about suitable shock absorbers 11 1 Adjusting the swivel angle The product can achieve a swivel angle of 90 The swivel angle can be readjusted by 3 per end stop via the sto...

Страница 13: ...the stop screws come into contact with the respective stop surfaces Reset the shock absorber when you change the swivel angle NOTICE The damping behavior changes as the oil in the shock absorber heat...

Страница 14: ...Slightly open the adjustment screw of the flow control valve Apply compressed air to the product Check the function Readjust the settings to the flow control valves and the shock absorbers as required...

Страница 15: ...e adjustment screw of the flow control valve until the desired swivel time is reached Weight of attachment parts workpieces too high Adjust the values to the technical data of the product End position...

Страница 16: ...Service whenever possible Dismantling and reassembling the product without authorization may result in complications as special installation equipment is required in some cases Zimmer GmbH accepts no...

Страница 17: ...specific technical documents were produced in accordance with Annex VII Part B of this Directive We undertake to provide the market supervisory bodies with electronic versions of special documents fo...

Отзывы: