11.3.1 Adjusting the shock absorber for the 0°/90° position
►
Perform the following steps for both shock absorbers.
1
2
3
►
Switch off the power supply.
►
Swivel the product to the desired position by hand.
►
Loosen the lock nut.
►
Rotate the shock absorber clockwise until the connecting plate
moves.
Ö
The piston rod of the shock absorber is pushed in as a result.
►
Unscrew the shock absorber counterclockwise one turn.
Ö
Damping is attenuated.
Ö
The shock absorber is set to maximum effect.
►
Loosely attach the lock nut.
►
Remove persons and objects from the swivel range.
►
Switch on the power supply.
►
Slightly open the adjustment screw of the flow control valve.
►
Apply compressed air to the product.
►
Check the function.
►
Readjust the settings to the flow control valves and the shock
absorbers as required.
►
Tighten the lock nut.
1
Limit stop
2
Lock nut
3
Shock absorber
11.4 Setting the sensors
NOTICE
To ensure reliable sensing, only those sensors sold by Zimmer GmbH and listed as accessories may be used.
►
Note that switching point shifts may occur if the sensors are exposed to an additional, external magnetic field.
INFORMATION
►
More information can be found in the installation and operating instructions of the sensor.