13
11.2 Setting the swivel time without shock absorbers
The swivel time is regulated via the air flow control.
►
Completely close the adjustment screws of the flow control valve for the first stroke.
►
Slowly fill the pneumatic circuit with compressed air.
►
Slowly open the adjustment screws of the flow control valves until the desired air flow control is reached.
11.3 Setting the swivel time with shock absorbers
When shock absorbers are used as the end position damping, the swivel time is regulated via the air flow control and the
shock absorber settings.
NOTICE
Shock absorbers may not be used as an end stop.
►
Make sure that the stop screws come into contact with the respective stop surfaces.
►
Reset the shock absorber when you change the swivel angle.
NOTICE
The damping behavior changes as the oil in the shock absorber heats up.
►
Enter the operating temperature settings for the shock absorbers.
•
After approximately 30 cycles in the cycle time that is selected later, the shock absorber reaches operating
temperature.
•
If a break time of > 1 minute is exceeded, no shock absorber warm-up is required.
INFORMATION
►
Check to ensure that there is uniform swivel movement and exhaust air flow-controlled movement to the end
positions.
►
If necessary, readjust the adjustment screws and shock absorbers.