background image

Z8FMC16100 Series Motor Control Development Kit

Quick Start Guide

QS005406-0111

Page 15 of 15

DO NOT USE THIS PRODUCT IN LIFE SUPPORT SYSTEMS.

LIFE SUPPORT POLICY

ZILOG’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL 
COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE 
EXPRESS PRIOR WRITTEN APPROVAL OF THE PRESIDENT AND GENERAL 
COUNSEL OF ZILOG CORPORATION. 

As used herein

Life support devices or systems are devices which (a) are intended for surgical implant 
into the body, or (b) support or sustain life and whose failure to perform when properly 
used in accordance with instructions for use provided in the labeling can be reasonably 
expected to result in a significant injury to the user. A critical component is any 
component in a life support device or system whose failure to perform can be reasonably 
expected to cause the failure of the life support device or system or to affect its safety or 
effectiveness.

Document Disclaimer

©2011 Zilog, Inc. All rights reserved. Information in this publication concerning the 
devices, applications, or technology described is intended to suggest possible uses and 
may be superseded. ZILOG, INC. DOES NOT ASSUME LIABILITY FOR OR 
PROVIDE A REPRESENTATION OF ACCURACY OF THE INFORMATION, 
DEVICES, OR TECHNOLOGY DESCRIBED IN THIS DOCUMENT. ZILOG ALSO 
D O E S   N O T   A S S U M E   L I A B I L I T Y   F O R   I N T E L L E C T U A L   P R O P E RT Y  
INFRINGEMENT RELATED IN ANY MANNER TO USE OF INFORMATION, 
DEVICES, OR TECHNOLOGY DESCRIBED HEREIN OR OTHERWISE. The 
information contained within this document has been verified according to the general 
principles of electrical and mechanical engineering.
Z8, Z8 Encore!, Z8 Encore! XP, Z8 Encore! MC, Crimzon, eZ80, and ZNEO are 
trademarks or registered trademarks of Zilog, Inc. All other product or service names are 
the property of their respective owners. 

Caution:

Содержание Z8FMC16100 Series

Страница 1: ...pply requirements to power the 3 phase motor supplied with the kit How to run the kit s preloaded sample code in standalone mode How to connect the kit to your development PC Running the sample code i...

Страница 2: ...hip s internal Flash memory This section describes a series of steps for setting up the kit and running the sample code in standalone mode Table 1 ZDSII System Requirements Recommended Configuration M...

Страница 3: ...t the motor leads to the spade lugs on the 3 Phase Motor Control Application Board as shown in Figure 2 Figure 1 MC MDS Board Mounted on 3 Phase Motor Control Application Board Step 2 Set Switches and...

Страница 4: ...406 0111 Page 4 of 15 Speed Potentiometer R7 to its mid point Refer to the Z8FMC16100 Series Motor Control Motor Control Development Kit User Manual UM0192 for detailed jumper descriptions Figure 2 Z8...

Страница 5: ...parately between the AC cord recepta cle on the end of the power supply and an electrical outlet Step 4 Connect the 5V DC Universal Power Supply to the MC MDS Board Connect the 5V DC power supply to t...

Страница 6: ...ug the 5V DC universal power supply from the MC MDS board Executing Sample Code in Debug Mode using ZDSII Observe the following steps to execute the sample code in debug mode using ZDSII 1 Stop the pr...

Страница 7: ...onnected to the development kit via a six circuit ribbon cable Install the USB Smart Cable for your operating system as described below Do not con nect power to either the MC MDS board or application...

Страница 8: ...d followed by the Found New Hardware USB Smart Cable dialog box c Select I don t have the disc Show me other options d Select Browse my computer for driver software advanced e Browse to one of the fol...

Страница 9: ...e Wizard should activate automatically after connecting the Zilog USB device for the first time b Click Next in the Found New Hardware Wizard after it has been activated c Select Search for a suitable...

Страница 10: ...ers on the MC MDS board are set as described in Step 2 Set Switches and Jumpers on page 3 b Connect and apply power to the development kit as described in Running in Standalone Mode on pages 2 through...

Страница 11: ...mples Z8FMC16 Z8FMC16_MotorDemo src f Select the motordemo zdsproj file and click Open The initial ZDSII program screen opens see Figure 4 To view the project source files double click the Project Fil...

Страница 12: ...ck OK i Click the Rebuild All icon to build the project Wait for the build to complete as indicated by the Build Complete confirmation in the Status window at the bottom of the screen j Click the Rese...

Страница 13: ...se motor should start running If the motor does not run start over from Step c on page 10 m Use the Direction Switch S1 to change the direction in which the motor spins Use Speed Potentiometer R7 to a...

Страница 14: ...S board After you have connected the 5V DC power supply to the MC MDS board the green 3 3V DC LED D4 must be illuminated If it is not illuminated verify that power is properly connected to the board a...

Страница 15: ...an be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness Document Disclaimer 2011 Zilog Inc All rights reserved Information in this...

Отзывы: