15
Zikodrive Motor Controllers are a product of Round Bank Engineering Ltd
Floor 2, Clifton Warehouse, Sowerby Bridge, West Yorkshire, HX6 2BY
–
www.zikodrive.com
- +44 (0) 1422647177
Voltage Minimum
This setting can be used to set a minimum voltage threshold at which the controller will cut out. This can be
useful in battery powered applications or a range of applications where input power may vary and could
potentially impact on motor performance. The settings for this range from 50-180 with 50 = 5V and 180 =
18V (and all increments in between).
Read Speed
This setting enables you to read the current speed of the motor.
Fault
If your controller has entered a fault state you can press “Tx” and it will return one of the following values,
enabling you to diagnose the cause of the fault.
1 = Over voltage limit (Gone above 30V)
2 = Under voltage limit (Gone below 5V)
3 = Overtemp limit (80 degrees Celsius)
4 = Drive chip fault (Fault resets after short period)
Analogue RPM Limit
This setting can be used to set a maximum speed that the analogue input will operate to. For example if
you would like the maximum speed to be set at 400rpm, then set the value to 400. This will then mean that
the maximum allowable speed the controller will run at in analogue mode will be 400rpm.