TR640IP
12760-0702-00
Page
15 / 18
www.ziehl.de
12
Disposal
The disposal must be carried out properly and environmentally friendly in accordance with the statutory
provisions.
13
Technical data
Supply voltage Us:
DC/AC 24 … 270 V, 0/50/60 Hz
Tolerance
DC 20,4 … 297 V
AC 20 … 297 V
Power consumption
< 3 W
< 7 VA
Relay outputs K2, K3, K4 (alarm 2, 3, 4)
Change over
Switching voltage
max. AC 300 V; DC 300 V
Inrush current normally open (NO)
AC 15 A 4s 10% ED
Min. voltage / current
12 V 10 mA
Conventional thermal current Ith
max. 5 A
Switching power
max. AC cos φ = 1
2000 VA
Switching power max. DC (ohm)
0,3 A 300 V; 0,4 A 120 V; 0,8 A 60 V; 8 A 30 V
Contact service life, electrical
cos φ = 1
cos φ = 1 -> 5 x 10
5
operations at 250 V / 2 A
Contact service life, mechanical
3 x 10
7
operations
Short circuit strength (NO)
Short circuit strength (NC)
4 A sluggish or circuit breaker B4
3,15 A sluggish
Rated operational current
AC-15
Ie = 3 A
Ue = 250 V
DC-13
Ie = 2 A
Ue = 24 V
DC-13
Ie = 0,4 A Ue = 120 V
DC-13
Ie = 0,2 A Ue = 240 V
UL electrical ratings
250 V ac, 3 A, general use
240 V ac, 1/4 hp, 2.9 FLA
120 V ac, 1/10 hp, 3.0 FLA
C300
Relay outputs K1 (alarm 1)
Change over
Switching voltage
max. AC 300 V; DC 300 V
Inrush current normally open (NO)
AC 25 A 4s / 50 A max. 1s 10% ED
Min. voltage / current
12 V 10 mA
Conventional thermal current Ith
max. 9 A
Switching power
max. AC cos φ = 1
2000 VA
Switching power max. DC (ohm)
0,3 A 300 V; 0,4 A 120 V; 0,8 A 60 V; 8 A 28 V
Contact service life, electrical
cos φ = 1
1 x 10
6
operations at 250 V / 6 A cos
φ = 1
2 x 10
5
operations at AC 250 V / 10 A cos
φ = 0,6
Contact service life, mechanical
3 x 10
7
operations
Short circuit strength (NO)
Short circuit strength (NC)
4 A sluggish or circuit breaker B4
3,15 A sluggish
Rated operational current
AC-15
Ie = 6 A
Ue = 250 V
DC-13
Ie = 2 A
Ue = 24 V
DC-13
Ie = 0,4 A Ue = 120 V
DC-13
Ie = 0,2 A Ue = 240 V
External inputs
approx. DC 18 V / 3,5 mA
Reset input Y1/Y2
Reset of locked alarms (dynamic)