6.10
Pulse generator for asynchronous motors (ZETADYN 3BF: X-ENC8, ZAdynpro: X-
ENC15)
•
Only TTL sinus encoders or incremental encoders are to be connected. HTL encoders may not be
connected. If an HTL encoder has been used on the ZETADYN 3BF it must be replaced with TTL
sinus or TTL rectangular encoder.
•
When connecting the encoder line to connection terminal X-ENC15 on the ZAdynpro, the "Adhe-
sion spring connection adaptor connector <-> D - SUB 15" (article number: 00152676) is to be
used.
•
The single cores must be connected to the adaptor connector as set out in the table.
ZETADYN 3BF
ZAdynpro
Encoder connection asynchronous mo-
tors (X-ENC8)
Encoder connection asynchronous mo-
tors (X-ENC15)
A
(A)
->
A
(12)
/A
(/A)
->
/A
(13)
B
(B)
->
B
(7)
/B
(/B)
->
/B
(14)
+5/8V_E
(5V)
->
5V_E
(4)
GND
(GND)
->
GND
(5)
->
(housing)
Connection terminal X-ENC8 ZETADYN 3BF
(TTL or sinus encoder)
Adaptor connector connection terminals
Connection terminal X-ENC15 ZAdynpro (TTL or sinus
encoder)