Please consider the references in the operating instructions of the ZAdynpro for the EMC-
compatible installation.
ZETADYN 3BF
ZAdynpro
Motor connection (X1)
Motor connection (X3)
U
->
U
V
->
V
W
->
W
PE
->
PE
6.5
Temperature monitoring of the motor (X-MT)
The ZAdynpro has no direct interface for the connection and evaluation of the motor temperature.
There are 2 ways to monitor the motor temperature:
1. Connection of the motor temperature monitoring to the elevator control.
2. Motor temperature monitoring with PTC using the tripping device type U-EK230E
If the elevator control does not provide a direct interface for motor temperature monitoring with PTC,
motor temperature monitoring can be performed using the tripping device type U-EK230E (part no.:
382008). The motor temperature monitoring is connected to the connection terminals (T1) / (T2) on
the tripping unit. The output signals at the connection terminals (11) / (12) / (14) on the tripping device
are connected to any input on the ZAdynpro.
The input must be con
fi
gured in the
Control
menu with the parameter
49:MOT_TEMP
.
Control
|
-
"
f_I08
47:CO
|
-
"
49:MOT_TEMP
Function I08
For further information on the tripping device type U-EK230E, refer to the operating instructions L-
BAL-E185-D 1902 Index 004; ZNr. 11660-0710-02.
Tripping device type U-EK230E
1
2
3
Display and control panel
1
Alarm red
2
Power ON green
3
Reset button
X-BR
ZAdynpro
BR3
(2) (5)
+24V_
OUT
Connection suggestion
Technical Information
Electrical installation
R-TIA19_04-D-GB 2030
Part.-No. 00163470-D-GB
8/26