6.4
Motor connection (ZETADYN 3BF: X1, ZAdynpro: X3)
"
Remove the motor contactors (6) and toroidal core (5) from the ZETADYN 3BF motor cable.
"
Connect the motor cable to connection terminal X2 on the ZAdynpro.
m
ax
.
2
0
0
m
m
m
a
x
.
2
00
m
m
m
a
x
.
2
00
m
m
1
2
3
4
6
5
7
8
9
10
ZETADYN 3BF
1
Mains supply terminal
2
Radio interference
fi
lter FEF
3
Line reactor
4
ZETADYN 3BF
5
Toroidal core for motor cable
6
Motor contactors
7
Brake resistor cable (shielded)
8
Motor cable (shielded)
9
Shielding (brake resistor cable)
10
Clip for contacting the shielding
ZAdynpro
1
ZAdynpro mains connection terminal
2
Power line
3
Motor cable (shielded)
4
Clip for contacting the shielding
5
Route electrical lines with the maximum
possible spacing
6
Line reactor
7
Mains supply terminal
8
Brake resistor cable (shielded)
9
Shielding (brake resistor cable)
•
A large area of the screening on the motor cable must be connected to the earth potential in the
immediate vicinity of the ZAdynpro. The screening must continue to the connection terminal as far
as possible.
•
We recommend
fi
xing the shielding on the mounting plate by means of a clip (see Fig.).
•
The mains supply line and the motor cable must be installed with the maximum possible spacing.
1
Fixing the shielding on the mounting plate
1
Clip
Technical Information
Electrical installation
R-TIA19_04-D-GB 2030
Part.-No. 00163470-D-GB
7/26