17.5.4
Saving parameters lists, printer lists and error lists
Parameter lists, printer lists and error lists can be saved on the memory card with allocation of the
ZAdyn4C serial number.
The following folder structure is created on the memory card:
"4CX\DEVICE\serial number"
. The
"LST" and "PAR" folders are created in the "Serial Number" folder. The error lists and printer lists are
saved in the "LST" folder, the parameter lists are saved in the "PAR" folder. The lists are named
according to the actual number of runs at the time of the data backup (e.g. "00000109.FLT" with 109
runs).
Saving parameters lists, printer lists and error lists
Statistics
->Memory Card
MMC Recorder
Encoder-adjust.
Select
"Memory Card"
menu
Con
fi
rming menu selection
Memory Card
|
-
"
SAV_ALL AUS
|
-
"
EIN
Select
"SAV_ALL"
parameter
Con
fi
rming menu selection
Select "SAV_ALL=EIN"
Con
fi
rm with the key.
Copy1:
_ _ _ _ _ _ _ _ _
The parameter list, the printer list and the error list are saved.
Memory Card
-> SAV_ALL Aus
SAV_PAR Aus
After the data backup the "SAV_ALL" parameter reassumes the
value "OFF".
17.5.5
Performing measurements
It is possible to perform measurements on the ZAdyn4C. These measurements are con
fi
gured in the
MMC-Recorder
menu and can be saved on the memory card. A description of the individual
parameters of the
MMC-Recorder
menu can be found in the chapter "Parameter List / Men
ü
MMC-
Recorder". The following folder structure is created on the memory card:
"4CX\DEVICE\serial
number\Rec"
. A sub-folder is created in the "Rec" folder for every measuring variant. The measure-
ments are saved in these sub-folders. The following sub-folders can be created:
•
"ERR"
folder: Save measurements which were interrupted by occurrence of an error.
•
"NORM"
folder: Save measurements for runs without errors.
•
"SHOT"
folder: Save measurements which were made with the "Stop&Shot" function.
The actual number of runs is used as a
fi
le name (e.g. "00000109.ZR3" for 109 runs).
Original operating instructions
ZAdyn4C
Special functions
R-TBA12_01-GB 2104 Index 012
Part.-No. 00163371-GB
187/224
1
7
S
p
e
c
ia
l
fu
n
c
ti
o
n
s
Содержание ZA dyn 4C
Страница 212: ...Original operating instructions ZAdyn4C Enclosure R TBA12_01 GB 2104 Index 012 Part No 00163371 GB 212 224 ...
Страница 213: ...19 Enclosure Original operating instructions ZAdyn4C Enclosure R TBA12_01 GB 2104 Index 012 Part No 00163371 GB 213 224 ...
Страница 214: ...Original operating instructions ZAdyn4C Enclosure R TBA12_01 GB 2104 Index 012 Part No 00163371 GB 214 224 ...
Страница 215: ...Original operating instructions ZAdyn4C Enclosure R TBA12_01 GB 2104 Index 012 Part No 00163371 GB 215 224 19 Enclosure ...
Страница 216: ...Original operating instructions ZAdyn4C Enclosure R TBA12_01 GB 2104 Index 012 Part No 00163371 GB 216 224 ...
Страница 217: ...19 Enclosure Original operating instructions ZAdyn4C Enclosure R TBA12_01 GB 2104 Index 012 Part No 00163371 GB 217 224 ...
Страница 220: ...Original operating instructions ZAdyn4C R TBA12_01 GB 2104 Index 012 Part No 00163371 GB 220 224 ...
Страница 221: ...19 Enclosure Original operating instructions ZAdyn4C R TBA12_01 GB 2104 Index 012 Part No 00163371 GB 221 224 ...
Страница 222: ...Original operating instructions ZAdyn4C R TBA12_01 GB 2104 Index 012 Part No 00163371 GB 222 224 ...
Страница 223: ...19 Enclosure Original operating instructions ZAdyn4C R TBA12_01 GB 2104 Index 012 Part No 00163371 GB 223 224 ...