(4) Evacuation type default
Con
fi
gure the parameter
F_PARA2 = UPS
in the
Parameter set 2
menu.
Parameter set 2
|
-
"
F_PARA2 UPS
|
-
"
UPS
Function parameter set 2
(5) Presetting the stator resistor in synchronous motors
In the
Parameter set 2 / R_U20
menu, enter the stator resistance of the synchronous motor used
Parameter set 2
|
-
"
R_U20
1.00
Ohm
|
-
"
1.00
Stator resistance (UPS
(6) Limit motor current
Limit the motor current by entering the available UPS power in the
"Parameter set 2/P_UPS"
menu.
Parameter set 2
|
-
"
P_UPS
1.0
kW
|
-
"
1.0
Max. load of the UPS
Calculating the available UPS power:
x
1 rating plate
- Control systempower consumption
- Electromechanical brakes power consumption
- Other consumers (car light,
…
) power consumption
=
Available UPS_power [W]
Information
Entering the UPS power determines the type of UPS evacuation.
Suf
fi
cient power:
An evacuation trip with the characteristics of an evacuation with optimum UPS
power is implemented.
Not enough power:
An evacuation trip with the characteristics of an evacuation with minimal UPS
power is implemented.
CAUTION!
Caution!
Setting the value for P_UPS too high can lead to an overloading or destruction of the UPS.
(7) Copying the parameters
In the menu
Parameter set 2/COPY
, select the function
PARA->2
. After copying, the parameter is
once again OFF.
Parameter set 2
|
-
"
COPY
Off
|
-
"
PARA1
R
2
Copy parameter
Information
The power failure detection and type of evacuation must be parameterised before copying the
parameters. Only a lower speed of the motor is possible because of the lower mains supply. The
maximum possible speeds for V_2 and V_3 are calculated during the copying process.
Original operating instructions
ZAdyn4C
Emergency evacuation
R-TBA12_01-GB 2104 Index 012
Part.-No. 00163371-GB
142/224
Содержание ZA dyn 4C
Страница 212: ...Original operating instructions ZAdyn4C Enclosure R TBA12_01 GB 2104 Index 012 Part No 00163371 GB 212 224 ...
Страница 213: ...19 Enclosure Original operating instructions ZAdyn4C Enclosure R TBA12_01 GB 2104 Index 012 Part No 00163371 GB 213 224 ...
Страница 214: ...Original operating instructions ZAdyn4C Enclosure R TBA12_01 GB 2104 Index 012 Part No 00163371 GB 214 224 ...
Страница 215: ...Original operating instructions ZAdyn4C Enclosure R TBA12_01 GB 2104 Index 012 Part No 00163371 GB 215 224 19 Enclosure ...
Страница 216: ...Original operating instructions ZAdyn4C Enclosure R TBA12_01 GB 2104 Index 012 Part No 00163371 GB 216 224 ...
Страница 217: ...19 Enclosure Original operating instructions ZAdyn4C Enclosure R TBA12_01 GB 2104 Index 012 Part No 00163371 GB 217 224 ...
Страница 220: ...Original operating instructions ZAdyn4C R TBA12_01 GB 2104 Index 012 Part No 00163371 GB 220 224 ...
Страница 221: ...19 Enclosure Original operating instructions ZAdyn4C R TBA12_01 GB 2104 Index 012 Part No 00163371 GB 221 224 ...
Страница 222: ...Original operating instructions ZAdyn4C R TBA12_01 GB 2104 Index 012 Part No 00163371 GB 222 224 ...
Страница 223: ...19 Enclosure Original operating instructions ZAdyn4C R TBA12_01 GB 2104 Index 012 Part No 00163371 GB 223 224 ...