background image

The assembly instructions and/or operating instructions are always readily available 
at the location where the device is being used, are complete and are in legible 
condition.

These persons are regularly instructed in all applicable questions regarding occupa-
tional safety and environmental protection and are knowledgeable regarding the 
assembly instructions and/or operating instructions and, especially, are familiar with 
the safety instructions contained therein.

All safety and warning notices attached to the device are never removed and remain 
legible.

2.9 Employment of external personnel

Maintenance and service work are frequently carried out by external employees who 
often do not recognize the speci

c situations and the thus resulting dangers.These 

persons must be comprehensively informed about the hazards in their area of activity.
You must monitor their working methods in order to intervene in good time if necessary.

3 Product overview

3.1 Operational area

The controller described is used for continuous speed adjustment on variable voltage 1~ 
motors used to drive ventilators or pumps.

3.2 Maintenance

The device must be checked for soiling and, if necessary, cleaned in periodic intervals.

3.3 Transport

The device is packed ex factory to suit the transport method previously agreed.

Always use the original packaging materials when transporting the device.

Avoid shocks and impacts to the device during the transport.

During manual handling the human lifting and carrying restrictions must be observed 
and adhered to.

3.4 Storage

The device must be stored in its original packaging in a dry and weather-proof room.

Avoid exposure to extreme heat and cold.

Avoid over-long storage periods (we recommend a maximum of one year).

3.5 Disposal / recycling

Disposal must be carried out professionally and in an environmentally friendly way in 
accordance with the respective national legal stipulations.

"

Separate the materials by type and in an environmentally friendly way.

"

If necessary, commission a specialist company with the waste disposal.

Operating Instructions 

Acontrol

 PSET6 / PSET10

Product overview

L-BAL-E141-GB 1925 Index 004

Part.-No. 

8/24

Содержание Acontrol PSET6

Страница 1: ...Acontrol PSET6 PSET10 Speed controller for variable voltage 1 fans Operating Instructions Keep for reference L BAL E141 GB 1925 Index 004 Part No english...

Страница 2: ...2 9 Employment of external personnel 8 3 Product overview 8 3 1 Operational area 8 3 2 Maintenance 8 3 3 Transport 8 3 4 Storage 8 3 5 Disposal recycling 8 4 Mounting 9 4 1 General notes 9 4 2 Minimu...

Страница 3: ...ions 16 6 3 Diagram setting signal and speed 16 6 4 Minimum speed cut off DIP 5 17 6 5 Hardstart function DIP 6 17 6 6 Operation with two variable output voltages two steps 17 7 Start up 18 7 1 Prereq...

Страница 4: ...ating instructions at any time Keep the operating instructions for continued use They must be passed on to all successive owners users and nal customers 1 2 Target group The operating instructions add...

Страница 5: ...arising from non intended use 2 2 Explanations of symbols Safety instructions are highlighted with warning triangles and are depicted according to the degree of hazard as follows Attention General haz...

Страница 6: ...ulations Personnel to be trained or instructed and apprentices are only permitted to work on the device under the supervision of an experienced person This also applies to personnel undergoing general...

Страница 7: ...e made on the device All planned modi cations must be authorized by the manufacturer in writing Use only genuine spare parts genuine wearing parts genuine accessories from ZIEHL ABEGG These parts were...

Страница 8: ...The controller described is used for continuous speed adjustment on variable voltage 1 motors used to drive ventilators or pumps 3 2 Maintenance The device must be checked for soiling and if necessary...

Страница 9: ...talled in a location where it will not be disturbed but at the same time can be easily accessed Depending on the housing model use supplied stoppers for cable inlets cut off necessary cable inlets res...

Страница 10: ...f an electrician in accordance with electrical engineering regulations The 5 electrical safety rules must be observed It is forbidden to carry out work on electrically live parts Cover neighbouring el...

Страница 11: ...onnect the shielding to one side only i e only to the control unit with the protective ground keep cable short and with as little inductance as possible 5 2 3 Harmonics current for devices 16 A Accord...

Страница 12: ...r noise this noise may be dominant in the lower speed range due to the occurrence of resonance For systems where noise is critical we recommend using our Fcontrol series frequency converters with inte...

Страница 13: ...ter factory setting DIP 8 ON 0 10 V modulation 0 100 Proportional the internal control of modulation with consideration n min and n max setting For enable OFF it goes not back to 0 V For motor fault t...

Страница 14: ...ed Diagnostics faults Fault indicated for line fault blown internal semiconductor fuse broken controller internal voltage supply overheating by the motor thermostats TB connected When switching off vi...

Страница 15: ...touch hazardous voltages directly 09 06 2011 v_pset_intern_bed VSD n max 0 100 n min 0 100 R15 ON OFF 10 9 8 7 6 5 4 3 2 1 DIP S1 R16 Potentiometer n min Minimal output voltage basic speed Setting ra...

Страница 16: ...Analog Out 1 Constant voltage 10 V for exter nal potentiometer 0 10 V modulation 0 100 9 no function 10 no function 6 3 Diagram setting signal and speed Setting via external signal or external potenti...

Страница 17: ...ng the mains voltage on the output voltage rises during the rmly programmed run up time to the given value DIP 6 ON Hardstart function ON For a safe starting of the connected fans the function Hard st...

Страница 18: ...late will not be exceeded 5 Make sure that no persons or objects are in the hazardous area 8 Diagnostics Faults Operating states are indicated by both internal status LEDs by a ashing code Code Relay...

Страница 19: ...de 09 06 2011 v_flash_code_pset VSD 2 1 ON OFF 8 1 If controller doesn t work correctly Information Setting of dip switches in principle only when device is not under voltage If the device is on mains...

Страница 20: ...or current approx 0 2 A Voltage supply e g for sensors 24 V 20 Imax 250 mA Output 0 10 V Imax 10 mA short circuit proof Max permissible ambient tem perature 55 C Min permissible ambient tem perature 0...

Страница 21: ...ature above the rated temperature see following table The average value measured during a 24 h period must be 5 K under the max ambient temperature For installation in a switch cabinet the device s di...

Страница 22: ...ltern with internal thermostats 2 A1 GND Ausgang Output 0 10 V Imax 10 mA 3 E1 GND GND Eingang Input 0 10 V 4 PEUN17K4 08 06 2011 TB TB D1 D1 24V Kontaktbelastung Contact rating max AC 250 V 5 A 5 1 L...

Страница 23: ...9 3 Dimensions mm PSET6 PSET10 Operating Instructions Acontrol PSET6 PSET10 Enclosure L BAL E141 GB 1925 Index 004 Part No 23 24...

Страница 24: ...4 info ziehl abegg de http www ziehl abegg de 9 5 Service information If you have any technical questions while commissioning or regarding malfunctions please contact our technical support for control...

Отзывы: