1. Precaution 

1.1  Safety Precaution 

„

 

To prevent injury to the user or other people 

and property damage, the following instructions 

must be followed. 

„

 

Incorrect operation due to ignoring 

instruction will cause harm or damage.   

„

 

Before service unit, be sure to read this 

service manual at first. 

 

1.2  Warning 

¾

 

Installation 

„

 

Do not use a defective or underrated circuit 

breaker. Use this appliance on a dedicated 

circuit. 

There is risk of fire or electric shock. 

„

 

For electrical work, contact the dealer, seller, 

a qualified electrician, or an Authorized service 

center. 

Do not disassemble or repair the product, there is risk 
of fire or electric shock. 

„

 

Always ground the product. 

There is risk of fire or electric shock. 

„

 

Install the panel and the cover of control box 

securely. 

There is risk of fire of electric shock. 

„

 

Always install a dedicated circuit and 

breaker. 

Improper wiring or installation may cause fore or 
electric shock. 

„

 

Use the correctly rated breaker of fuse. 

There is risk of fire or electric shock. 

„

 

Do not modify or extend the power cable. 

There is risk of fire or electric shock. 

„

 

Do not install, remove, or reinstall the unit 

by yourself(customer). 

There is risk of fire, electric shock, explosion, or 
injury. 

„

 

Be caution when unpacking and installing 

the product. 

Sharp edges could cause injury, be especially careful 
of the case edges and the fins on the condenser and 
evaporator. 

„

 

For installation, always contact the dealer or 

an Authorized service center. 

There is risk of fire, electric shock, explosion, or 
injury. 

„

 

Do not install the product on a defective 

installation stand. 

It may cause injury, accident, or damage to the 
product. 

„

 

Be sure the installation area does not 

deteriorate with age. 

If the base collapses, the air conditioner could fall 
with it, causing property damage, product failure, and 
personal injury. 

„

 

Do not let the air conditioner run for a long 

time when the humidity is very high and a door or 

a window is left open. 

Moisture may condense and wet or damage 
furniture. 

„

 

Take care to ensure that power cable could 

not be pulled out or damaged during operation. 

There is risk of fire or electric shock. 

„

 

Do not place anything on the power cable. 

There is risk of fire or electric shock. 

„

 

Do not plug or unplug the power supply 

plug during operation. 

There is risk of fire or electric shock. 

„

 

Do not touch (operation) the product with 

wet hands. 

There is risk of fire or electric shock. 

„

 

Do not place a heater or other appliance 

near the power cable. 

There is risk of fire and electric shock. 

„

 

Do not allow water to run into electric parts. 

It may cause fire, failure of the product, or electric 
shock. 

„

 

Do not store or use flammable gas or 

combustible near the product. 

There is risk of fire or failure of product. 

„

 

Do not use the product in a tightly closed 

space for a long time. 

Oxygen deficiency could occur. 

„

 

When flammable gas leaks, turn off the gas 

and open a window for ventilation before turn the 

product on. 

Do not use the telephone or turn switches on or off. 
There is risk of explosion or fire. 

„

 

If strange sounds, or small or smoke comes 

from product. Turn the breaker off or disconnect 

the power supply cable. 

There is risk of electric shock or fire. 

„

 

Stop operation and close the window in 

storm or hurricane. If possible, remove the 

product from the window before the hurricane 

Содержание S 3025

Страница 1: ...S3025 S3032...

Страница 2: ...4 Air purging of the piping and indoor unit 13 7 5 Pumping down Re installation 15 7 6 Re air purging Re installation 16 7 7 Balance refrigerant of the 2 way 3 way valves 17 7 8 Evacuation 18 7 9 Gas...

Страница 3: ...9 14 Auto Restart function 29 9 15 Outdoor chassis heating cable optional 29 10 Troubleshooting 30 10 1 Indoor Unit Error Display 31 10 2 Diagnosis and Solution 32 10 3 Key parts checking 35...

Страница 4: ...a defective installation stand It may cause injury accident or damage to the product Be sure the installation area does not deteriorate with age If the base collapses the air conditioner could fall wi...

Страница 5: ...directly It may cause corrosion on the product Corrosion particularly on the condenser and evaporator fins could cause product malfunction or inefficient operation Operational Do not expose the skin d...

Страница 6: ...3 your skin or clothes wash it well with clean water Do not use the remote of the batteries have leaked The chemical in batteries could cause burns or other health hazards...

Страница 7: ...er direction according to operation mode Turbo high med low breeze Restarting is for approx 3 minutes Prevent the water being frozen on evaporator by sensing the evaporator pipe temperature in cooling...

Страница 8: ...on mode Hydrophilic aluminum fin It is only operated in the heating operation mode except defrosting operation Anti rust cabinet Valve protection cover 4 way valve control Made from electrolytic zinc...

Страница 9: ...6 3 Dimension 3 1 Indoor Unit S3025 S3032 Model W mm H mm D mm S3025 710 250 189 S3032 790 275 190...

Страница 10: ...7 3 2 Outdoor Unit...

Страница 11: ...KSD301 Capacitor uF No No Compressor Refrigerant oil ml ESTER OIL VG74 370ml ESTER OIL VG74 370ml Model RPG13H RPG20E Brand Welling Welling Input W 34 45 Capacitor uF 1 2 1 5 Indoor fan motor Speed hi...

Страница 12: ...piping Max difference in level m 8 8 Connection wiring No No Plug type 16A 16A Thermostat type Electronic control Electronic control Operation temp 17 30 17 30 Ambient temp 15 50 15 50 Application ar...

Страница 13: ...10 5 Refrigerant cycle diagram...

Страница 14: ...11 6 Wiring diagram 6 1 Indoor Unit S3025 S3032...

Страница 15: ...12 6 2 Outdoor Unit S3025 S3032...

Страница 16: ...andard length m Max Elevation B m Max Length A m Additional refrigerant g m 9k 3 8 9 52 1 4 6 35 5 8 20 20 12k 3 8 9 52 1 4 6 35 5 8 20 20 Caution Capacity is based on standard length and maximum allo...

Страница 17: ...e s service port Using the hexagonal wrench to press the valve core pin discharge for three seconds and then wait for one minute 5 Use torque wrench to tighten the service port cap to a torque of 1 8...

Страница 18: ...hose with the push pin to the gas service port 5 Air purging of the charge hose Open the low pressure valve on the charge set slightly to purge air from the charge hose 6 Set the 2 way valve to the cl...

Страница 19: ...te repeat 3 times After purging the air use a torque wrench to tighten the flare nut to on the 2 way valve 4 Check the gas leakage Check the flare connections for gas leakage 5 Discharge the refrigera...

Страница 20: ...ce port 3 Open the valves Low side on the charge set and discharge the refrigerant until the gauge indicates 0 05 to 0 1Mpa If there is no air in the refrigeration cycle the pressure when the air cond...

Страница 21: ...ved toward 0 1 Mpa 76 cmHg vacuum of 4 mmHg or less 3 Close the valve Low side on the charge set turn off the vacuum pump and confirm that the gauge needle does not move approximately 5 minutes after...

Страница 22: ...fied amount of refrigerant if can be charged with a little at a time approximately 150g each time0 while operating the air conditioner in the cooling cycle however one time is not sufficient wait appr...

Страница 23: ...0 77 0 78 0 72 0 73 0 74 Cooling Power Input KW Remark Indoor room temperature 27 19 Outdoor temperature 35 Indoor fan speed High 15 Cooling Capacity KW Cooling Characteristics Outdoor Ambient Temper...

Страница 24: ...3 5 3 4 3 2 3 3 3 6 3 7 3 8 10 11 12 13 14 5 6 7 8 9 0 98 1 00 1 02 1 04 0 92 0 94 0 96 Heating Power Input KW Remark Indoor room temperature 20 Outdoor temperature 7 6 Indoor fan speed High 15 3 1 C...

Страница 25: ...tes when TIMER is set ON OFF 9 2 2 LED display control function Pressing LED display button on remote controller will turn off all displays on indoor unit while pressing once again all displays will r...

Страница 26: ...all modes the indoor fan will operate 10 seconds later than the action of louver 9 3 9 Compressor preheating function 1 Preheating permitting condition If T4 outdoor ambient temperature 3 and the mac...

Страница 27: ...s or more within 10 seconds make sure indoor unit receives these signals the machine will turn into rating capacity test mode the buzzer will make a beep sound for 2 seconds continuously Also indoor f...

Страница 28: ...reezing protection condenser high temperature protection and outdoor unit frequency limit are valid and they are the same as that in cooling mode 9 6 4 Horizontal louver action is the same as that in...

Страница 29: ...cend the current frequency one grade Zone D Compressor stops after running with F1 for 60 minutes or when Th 6 9 7 4 Outdoor unit current control in heating mode 9 7 5 Indoor heat exchanger high tempe...

Страница 30: ...sfied defrosting will finish and the machine will turn to normal heating mode a T3 rises to be higher than 12 b T3 rises to be higher than 8 and remains for 80 seconds c The machine has run for 10 min...

Страница 31: ...button In these two modes the machine can be changed by remote controller to any other mode at any moment 9 9 2 When the machine is off pressing the touch button once the unit will enter forced auto...

Страница 32: ...or SLEEP button on controller the machine will turn into sleep mode 2 When cooling the setting temperature rises 1 be lower than 30 every one hour 2 hour later the rising stops and indoor fan is fixed...

Страница 33: ...apacitors in PCB and relative circuit in outdoor unit even shut down the power supply electricity power still are kept in capacitors do not forget to discharge the electricity power in capacitor Elect...

Страница 34: ...Indoor fan speed out of control E5 Open or short circuit of outdoor ambient or condenser temperature sensor E6 Open or short circuit of indoor room or evaporator temperature sensor P0 Inverter module...

Страница 35: ...ection of L N S and GND good Is the GND connection on outdoor PCB good NO NO Reconnect and retest again Is the LED4 red on outdoor PCB bright and LED1 yellow blinking Replace outdoor e box Yes Yes The...

Страница 36: ...n Is the failure cleared NO YES Check the compressor NO Is the indoor temperature and evaporator sensor connector and connection good Repair the connector and reconnect Replace the sensor and check if...

Страница 37: ...ce of inverter compressor is it right YES Replace inverter compressor Reconnect and retry NO NO Check refrigerant system such as clogging of capillary etc Is the power supply good Be sure the power su...

Страница 38: ...inding by using the multi meter 10 3 3 Indoor Fan Motor Model RPG13H for S3025 RPG20E for S3032 Measure the resistance value of each winding by using the multi meter Position Resistance Value Blue Red...

Страница 39: ...st temp Te sensor Measure the resistance value of each winding by using the multi meter Some frequently used R T data for T1 T2 T3 and T4 sensor Temperature 5 10 15 20 25 30 40 50 60 Resistance Value...

Страница 40: ...37...

Отзывы: