35
10.3 Key parts checking.
10.3.1. Compressor checking
(Model: DA89X1C-20EZ).
Measure the resistance value of each winding by using the multi-meter.
10.3.2 Outdoor Fan Motor
(Model: YDK24-6P).
Measure the resistance value of each winding by using the multi-meter.
10.3.3 Indoor Fan Motor
(Model:RPG13H for S3025, RPG20E for S3032).
Measure the resistance value of each winding by
using
the multi-meter.
Position
Resistance Value
Blue - Red
Blue - Black
Red - Blue
0.71
Ω
(20
Ԩ
)
Position
Resistance Value
Black - Red
418
Ω
±8% (20
Ԩ
)
Blue - Red
277
Ω
±8% (20
Ԩ
)
Yellow - Blue
277
Ω
±8% (20
Ԩ
)
Position
Resistance Value
Black - Red
575
Ω
±8% (20
Ԩ
) for RPG13H
387
Ω
±8% (20
Ԩ
) for RPG20E
White - Black
558
Ω
±8% (20
Ԩ
) for RPG13H