background image

18 

SkyZhone 1600, 1400, 1200 Hardware Install Guide

 

Ethernet (plus Aux Power) SOCKET Connector 

 

Figure 6: Ethernet (plus Aux Pwr) SOCKET connector

 

 

If the Ethernet connection is unused it must have a dust cap installed to maintain an IP66 rating 
for the unit. 

 

Table 4: Ethernet (plus Aux Pwr) Socket Connector   
 

Pin 

Signal 

TX_P 

TX_N  

RX_P 

RX_N  

No Connection 

48V 

Return_48V 

No Connection 

  

 

Note:  

The Ethernet connector is capable of sourcing power to other devices. Some devices may not  

be compatible with this feature. In that case, do not connect the wires that supply the power, or use the 

Data Only cable.

 

 

Содержание SkyZhone 1600

Страница 1: ...SkyZhone 1600 1400 1200 Hardware Installation Guide For software version 1 2 2 x Document Part Number 830 01818 02 June 2008...

Страница 2: ...l warning notices and instructions marked on the product or included in the manual 1 The SkyZhone Model 1x00 products are AC powered devices conforming to UL 60950 1 standards The AC Power cable must...

Страница 3: ...ng lug and firmly tighten the grounding screw see Figure 18 on page 39 Connect the other end of the grounding wire to a grounded surface or another earth ground such as a metal rod This ground must be...

Страница 4: ...with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which the user will be r...

Страница 5: ...Logic ground is internally bonded to the Safety Ground chassis Proper Safety Grounding is required to insure proper operation and protection from lightning strikes and surges A copper ground lug is pr...

Страница 6: ......

Страница 7: ...r PLUG Connector 20 Grounding 20 Cables 21 Console Cable 21 Ethernet Data Cable 22 Ethernet Data and Power Cable 23 Ethernet Data and Power Cable Early Version 24 Chapter 2 Preparing for Installation...

Страница 8: ...and Certifications 47 Contacting Global Service and Support 47 Technical Support 47 Service Requirements 47 EMI Notices 48 United States EMI Notice 48 Canada EMI Notice 48 Supplier s Declaration of Co...

Страница 9: ...ocument to alert users to information that is instructional warns of potential damage to system equipment or data and warns of potential injury or death Carefully read and follow the instructions incl...

Страница 10: ...typed by users Fixed Bold Italic Used in code examples for variable text typed by users Italic Used for book titles chapter titles file path names notes in body text requiring special attention sectio...

Страница 11: ...the First Mile MALC Multi Access Line Concentrator MIB Management Information Bases NAT Network Address Translation NMS Network Management System RADIUS Remote Authentication Dial In User Service SHDS...

Страница 12: ...u want to return a product for repair under warranty contact GSS The contact information is as follows E mail support zhone com Telephone North America 877 ZHONE20 877 946 6320 Telephone International...

Страница 13: ...to maximize the receive signal strength from typical low power IEEE 802 11b g client devices MIMO enables the SkyZhone to maintain a reliable link at distances up to 50 greater than non MIMO solution...

Страница 14: ...ardware Install Guide SkyZhone also includes an Ethernet with Aux Power port which provides for connectivity from the SkyZhone access point to a video camera or other 48V accessories This port can pro...

Страница 15: ...smission of 2 4 GHz 802 11b g and 4 9 GHz 802 11a using two separate radios A single 10 100 Ethernet is used for backhaul 120VAC power is required SkyZhone 1400 Wi Fi Access Point Supports wireless ra...

Страница 16: ...ge both horizontally and vertically In Figure 1 on page 1315 note that the 4 9 GHz 802 11a radio uses the bottom two antennas and the 2 4 GHz 802 11b g radio uses the top three antennas The 2 4 GHz ra...

Страница 17: ...tors Port connectors are located on either side of the SkyZhone unit Figure 4 SkyZhone 1x00 port connectors Note Sealing caps provided with the unit must be placed on unused connectors Without these c...

Страница 18: ...installed to maintain an IP66 rating for the unit Table 4 Ethernet plus Aux Pwr Socket Connector Pin Signal A TX_P B TX_N C RX_P D RX_N E No Connection F 48V G Return_48V H No Connection Note The Ethe...

Страница 19: ...onfigure the SkyZhone before mounting Any cabling to the console connector must be removed from the permanent installation to avoid shock hazards Dust caps must be installed to maintain an IP66 rating...

Страница 20: ...ble Table 5 AC Power PLUG connector pinouts Pin Signal Color of matching cable wire 1 Neutral White 2 No connection 3 Line Black GND Chassis GND Green Note The SkyZhone 1x00 products are shipped with...

Страница 21: ...a 9 pin DIN connector on the other end Note that the SkyZhone 1x04 models use a different console cable The cables are not interchangeable Part number 810 07906 01 Souriau UTS6JC1210SX104C5 5 foot con...

Страница 22: ...router or switch This cable can be ordered in lengths of 5 30 or 100 feet Part number 810 08166 01 Souriau UTS6JC1210PX103A5 5 foot Ethernet Cable 810 08167 01 Souriau UTS6JC1210PX103A30 30 foot Ether...

Страница 23: ...could occur to the auxiliary device This cable can be ordered in lengths of 5 30 or 100 feet Part number 810 08168 01 Souriau UTS6JC1210PX103B5 5 foot Ethernet and Power Cable 810 08169 01 Souriau UT...

Страница 24: ...fferences Note Before crimping a new RJ connector on the cable double check the part number in order to verify the color codes of the wire used in the cable Table 10 Ethernet plus Aux Pwr External Cab...

Страница 25: ...the unit in an area where trees buildings and large steel structures do not obstruct radio signals to and from the antenna Be sure to consider the future tree growth and construction when considering...

Страница 26: ...I F Frequency Band 2 412 2 462 GHz 2 4 GHz Wireless 4 900 4 990 GHz 4 9 GHz Wireless Channel Width 20 MHz 2 4 GHz Wireless 20 MHz 4 9 GHz Wireless Output Power EIRP 1 15 W 2 4 GHz Wireless 4 74 W 4 9...

Страница 27: ...Power 48V DC up to a maximum 35W Data Path VLAN support IEEE 802 1Q Traffic Prioritization IEEE 802 1p 802 11e IP TOS Number of Priority Queues 4 Traffic Classification Based on priority bits protocol...

Страница 28: ...rizontal and level It is best to mount the SkyZhone access point to a metal structure The metal mounting brackets are designed to make good contact with the pole thereby assuring good quality connecti...

Страница 29: ...tamper resistant screws 1 driver bit for the tamper resistant screws Customer Supplied Equipment For installation you need the following items Large slotted screw driver to secure the banding clamps...

Страница 30: ...point to any pipe or pole 1 Attach screw clamp bands to the pole mounting plate by threading them through the slots on the mounting plate The slots are for either horizontal or vertical mounting on la...

Страница 31: ...re 8 Mounting plate strapped around a pole 3 Tighten and if necessary trim off any excess tension band 4 Secure the mounting bracket to the pole The SkyZhone shelf is attached to the poll mounting bra...

Страница 32: ...s are connected to the top of the unit The two shorter antennas are mounted to the bottom of the unit The antennas are not interchangeable It is critical that the longer antennas are on the top and th...

Страница 33: ...provide strain relief if needed Note The previous procedure showed the SkyZhone station being mounted to a vertical pole The same instructions apply to the installation on a horizontal pole or any oth...

Страница 34: ...cover is used to hide the unit for aesthetic purposes This cover can be painted which allows the unit to blend in with the building Figure 11 displays a fully assembled SkyZhone with its cover Figure...

Страница 35: ...ecurely 1 Find a flat surface that is at least 24 inches tall and 36 inches wide 2 Drill the holes in the wall to align with the corresponding holes in the mounting bracket See Figure 13 3 Obtain the...

Страница 36: ...ng to ensure in proper orientation Use a 1 4 inch drill masonry bit to install a 1 inch plastic insert to secure the cover and the aluminum frame to the concrete wall with the appropriate screws Figur...

Страница 37: ...nes on the bottom of the unit 9 Slide the SkyZhone station onto the wall mounting bracket 10 Secure the SkyZhone to the wall mounting bracket with the 4 four tamper resistant screws provided in the in...

Страница 38: ...38 SkyZhone 1600 1400 1200 Hardware Install Guide Figure 16 Wall Mount Kit Final Assembly Figure 17 Example of a wall mounted SkyZhone...

Страница 39: ...completed before applying AC power to the SkyZhone unit Connect a length of 10 AWG solid bare copper wire to the wire grounding lug of the unit and tighten the grounding nut See Figure 18 Connect the...

Страница 40: ...r PC that is compatible with the new IP address that you configured in the SkyZhone unit Also if any changes have been made to the VLAN definitions the corresponding changes will have to be made in th...

Страница 41: ...his example VLAN 2 is the management VLAN config vlan vlanconfig addvlan vlan_name management vlanid 2 config vlan vlanconfig addport interface eth1 vlanid 2 tagged config vlan portdefaults vlanport e...

Страница 42: ...e Internal Bridge LAN IP 192 168 1 1 192 168 1 1 192 168 1 1 Netmask 255 255 255 0 255 255 255 0 255 255 255 0 Broadcast Address 192 168 1 255 192 168 1 255 192 168 1 255 Interface Name brvlan1 brvlan...

Страница 43: ...N A WLAN 1 SSID 4 N A WLAN 1 SSID security N A None None WLAN 1 Admin State N A Down Down WLAN 1 Radio Name N A 4 9 GHz 4 9 GHz WLAN 1 Hardware Mode N A a a WLAN 1 Rates N A auto auto WLAN 1 Channel P...

Страница 44: ...hone 1400 Single 4 9 GHz Longitude 0 0 0 Date and Time NTP disable disable disable NTP Server 0 0 0 0 0 0 0 0 0 0 0 0 Date Time Time Zhone Eastern Eastern Eastern Save Auto save Running Config Disable...

Страница 45: ...fication as to whether it is operating correctly or needs to be replaced Figure 19 LED Location Table 7 States of the LED light Color Operation Description Red On solid Power is on and the software is...

Страница 46: ......

Страница 47: ...escription of the issue Technical Support If you require assistance with the installation or operation of your product or if you want to return a product for repair under warranty contact GSS The cont...

Страница 48: ...ohibited for use with this device The required antenna impedance is 50 ohms The 4 9 GHz band has been designed to operate with the antennae listed below and having a maximum gain of 5 3 dBi Antennae n...

Страница 49: ...1600 bearing the FCC identification numbers PJZSZ1224 PJZSZ1424 PJZSZ1624 complies with the Federal Communications Commission s FCC Rules and Regulations pursuant to part 15 subpart C 14 247 part 15 C...

Страница 50: ...Canadian Telephone Network NOTICE This equipment has been certified to ITU T G991 2 CE Marking When the product is marked with the CE mark on the equipment label a supporting Declaration of Conformit...

Отзывы: