33
Suppress Alarm(s): After an alarm is triggered, the same alarm will not be reported within the set time.
Clear Alarm(s): After an alarm is triggered,
a.
If the same alarm is not triggered within the set time, the alarm will be cleared and the same
alarm can be reported again.
b.
If the same alarm is triggered within the set time, the alarm will not be cleared until the suppress
alarm time expires. Then the same alarm can be reported again.
5.
Set actions to be triggered by motion detection alarm and the plan.
The following table describes the major alarm-triggered actions and how to set a plan.
Item
Description
Alarm
Output
1
Select the check box. This setting is the alarm output interface linked to motion detection alarm.
Note:
When an alarm is reported, the camera triggers alarm output so as to trigger actions by a
third-party device.
PTZ to
Preset
Select the check box and set the preset linked to motion detection alarm.
Note:
Make sure you have set presets. Otherwise, you cannot set this parameter. For details about
how to set a preset, see
Setting Presets
.
When an alarm is reported, the PTZ camera automatically goes to the preset to capture video in
the correct scene.
Upload
to FTP
With
Upload to FTP
selected, the camera will automatically upload snapshots to the specified FTP
server when an alarm is triggered.
Note:
Make sure you have completed
FTP
and
Configuring Capture
before using this function.
Trigger
E-mail
With
Trigger E-mail
selected, the camera will automatically send snapshots to the specified E-mail
address when an alarm is triggered.
Note:
Make sure you have completed
and
Configuring Capture
before using this function.
Trigger
Storage
With
Trigger Storage
enabled, the camera automatically starts recording after an alarm is
triggered.
Note:
Make sure you have completed the post-recording time settings before using this function.
Enable
Plan
Select the check box and set the start and end times during which motion detection alarm is
effective. You can directly drag the mouse to draw a plan and click
Edit
to edit time periods in the
table. The time periods cannot overlap. The camera reports alarms during the specified period(s)
only.
You can select from Monday to Sunday and set four periods for each day.