![ZHEJIANG XIANFENG MACHINERY DKC400 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/zhejiang-xianfeng-machinery/dkc400/dkc400_user-manual_3605344008.webp)
DKC400(U) & DKC400(U)Y SLIDING GATE OPERATOR USER’S MANUAL
9.
Limit switch: CL (Close limit), CO (Com), OP (Open limit)
,
DC12V (Output power supply)
CL
COM
OP
N.C. (For N.C. limit switch)
CL
COM
OP
N.O. (For N.O. limit switch)
Limit switch mode is adjustable by DIP-switch. (See table 3)
Schematic diagram
10.
Output power supply: +12V (DC +12V), COM (CO)
,
DET (Loop detector), I.R. (Infrared
N.C)
COM
GND
+12V
Out
COM
I.R
COM
+12V
Terminal
X8, No.10
Terminal
X8, No.10
I.R
COM
Out
COM
AC24V
AC24V
Terminal
X5,No.11
Infrared
Control board
Infrared
Control board
Infrared with DC input
Infrared with AC input
Loop detector with DC input
Control board
Loop detector
Terminal
X8, No.10
+12V
COM
DET
COM
Out
+12V
GND
COM
Loop detector with AC input
Control board
Loop detector
Terminal
X5,No.11
AC24V
AC24V
COM
Out
COM
DET
Terminal
X8, No.10
Schematic diagram
11.
Output power supply: AC24V
12.
Power Indicator: LED
13.
Learn button: AN
14.
Force Adjustor (VR1): Clo, Counterclockwise –
15.
Power Transformer
16.
Sampling Transformer: 110V/8.8V 4W
17.
Alarm Lamp: DKC400Y/XF24W: AC220V; DKC400UY/XF24U: AC110V
18.
Motor Capacitor
19.
Motor: U (com), V (Positive direction), W (Opposite direction), E (grounding)
20.
Power Input: E (Earth), L (Live), N (Neutral)
DKC400Y/XF24W: AC220V; DKC400UY/XF24U: AC110V
13
DKC400(U) & DKC400(U)Y SLIDING GATE OPERATOR USER’S MANUAL
Fig.15 KZB05 control board with relay
14