DKC400(U) & DKC400(U)Y SLIDING GATE OPERATOR USER’S MANUAL
stop cycle.
Button 1, button 2 and button 3 are used to open or close the gate. Button 4 is
available to set pedestrian mode. Note: if you canceled the pedestrian mode, the
function of button 4 is same as the other three buttons.
You can program/learn button 1, button 2, button 3 individually. You also can
program/learn two buttons or three buttons together, but you need repeat the
program/learn process if you want to use more than one button.
Warning: Notify the users that the gate is never to be operated unless it is in full view.
Verify open direction: If the gate does not move in the desired direction, then you will
need to reverse the motor operating direction, you can do this by exchanging wires ‘V’
and ‘W’, ‘OP’ and ‘CL’.
Tab. 3 DIP-switch
(See Fig.14 KZB01, Fig.15 KZB05 terminal 5)
Position
DIP-switch
Function
1
ON
Limit switch mode is NC.
OFF
Limit switch mode is NO.
2
ON
Auto-close function and auto-close function of pedestrian
mode are available.
OFF
Both Auto-close function and auto-close function of
pedestrian mode are shut off.
3
ON
Programming / In this position the control board is in
programming condition, NOT USE condition.
OFF
Normal / In this position the control board can be normally
used.
(See Fig.16 KZB13 terminal 18)
Position
DIP-switch
Function
1
ON
Programming / In this position the control board is in
programming condition, NOT USE condition.
OFF
Normal / In this position the control board can be normally
used.
2
ON
Auto-close function and auto-close function of pedestrian
mode are available.
OFF
Both Auto-close function and auto-close function of
pedestrian mode are shut off.
3
ON
Limit switch mode is NC.
OFF
Limit switch mode is NO.
DKC400(U) & DKC400(U)Y SLIDING GATE OPERATOR USER’S MANUAL
Set auto-close function (This feature can be selected to make the gate stay open for some
seconds before it automatically closes. The auto-close time can be adjusted to between 0 and
44 seconds.): for control board KZB01 or KZB05, please turn on the second and the third
DIP-switch to ON position (
Note: for control board KZB13, please turn on the first and the
second DIP-switch to ON position
). Press the remote control button (button 1, button 2 or
button 3) that has been programmed to open the gate (see
Verify open direction
section).
Stop the gate at any position by pressing the same button, wait for some seconds according to
your requirements (the range is 1~44 sec.), this period of time is regarded as ‘auto-close time’.
Close the gate by pressing the same button. Press the button again to stop the gate or the
gate will stop at its closed position automatically if the limit switch is reached. After this setup is
complete, return DIP-switch 3 to OFF position immediately
(for control board KZB13, return
DIP-switch 1 to OFF)
. Thus the auto-close function has been set.
Cancel auto-close function: for control board KZB01 or KZB05, please turn on the second and
the third DIP-switch to ON position (
Note: for control board KZB13, please turn on the first
and the second DIP-switch to ON position
). Press the remote control button (button 1,
button 2 or button 3) that has been programmed to open the gate (see
Verify open direction
section). Stop the gate at any position by pressing the same button, wait until the gate close
automatically (45 sec.). Press the same button to stop the gate or the gate will stop at its
closed position automatically if the limit switch is reached. After this setup is complete, return
DIP-switch 3 to OFF position immediately
(for control board KZB13, return DIP-switch 1 to
OFF)
. Thus the auto-close function has been canceled.
Pedestrian mode: Pedestrian mode can be used to open gate about 1.5 meters for people
pass through.
﹡
Set width of pedestrian mode: for control board KZB01 or KZB05, please turn on the second
and the third DIP-switch to ON position (
Note: for control board KZB13, please turn on the
first and the second DIP-switch to ON position
). Press button 4 to open the gate (see
Verify open direction
section), Wait until the gate travels the distance according to your
requirements (the distance range is 0.3m~1.5m or wait for 3~10 sec.), it is regarded as ‘the
width of pedestrian mode’. Then press the same button/button 4 to stop the gate, wait for
some seconds (1~ 44 sec.). Close the gate by pressing the same button/button 4. Press the
same button again to stop the gate or the gate will stop at its closed position automatically if
the limit switch is reached. After this setup is complete, return DIP-switch 3 to OFF position
immediately
(for control board KZB13, return DIP-switch 1 to OFF)
. Thus the
width of
pedestrian mode
has been set.
If you open the gate with button 4, the gate will stop at the expected position that you have set.
21
22