![ZHEJIANG XIANFENG MACHINERY DKC400 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/zhejiang-xianfeng-machinery/dkc400/dkc400_user-manual_3605344010.webp)
DKC400(U) & DKC400(U)Y SLIDING GATE OPERATOR USER’S MANUAL
Fig.16 KZB13 control board with silicon controlled rectifier & relay
17
DKC400(U) & DKC400(U)Y SLIDING GATE OPERATOR USER’S MANUAL
Wiring notes for control board (KZB13)
1. Fuse: DKC400Y/XF24W: 5A, Ø5x20; DKC400UY/XF24U: 10A, Ø5x20
2. Power Input: E (Earth), L (Live), N (Neutral)
DKC400Y/XF24W: AC220V; DKC400UY/XF24U: AC110V
3. Motor: U (com), V (Positive direction), W (Opposite direction), E (grounding)
4. Capacitor: DKC400Y/XF24W:14uf; DKC400UY/XF24U: 55 uF
5. Alarm lamp: DKC400Y/XF24W: AC220V; DKC400UY/XF24U: AC110V
6. Sampling transformer: 220V/12V 1W
7. Force Adjustor (VR): Clo, Counterclockwise –
8. Power Transformer
9. MCU: PIC 16C57C
10. Power indicator: LED1
11. Output power supply: AC24V
12. Memory Card: 93C66
13. Limit switch: CL (Close limit), CO (Com), OP (Open limit)
,
DC12V (Output power supply)
CL
COM
OP
N.C. (For N.C. limit switch)
CL
COM
OP
N.O. (For N.O. limit switch)
Limit switch mode is adjustable by DIP-switch. (See table 3)
Schematic diagram
14. Three button switch / single button switch (keypad)
Three button switch (normally open, three-button mode): T (Stop), G (Close), K (Open), COM
(Common)
N.O.
Button switch
T
G
K
COM
COMMON
STOP
CLOSE
OPEN
COM
K
G
T
Control board
terminal X7 No.14
Schematic diagram
Wiring diagram
Single button switch / Keypad (normally open, single-button mode): T (Not used), G (Open
priority), K (Open/stop/close), COM (Common)
To install the keypad attach one lead of your keypad to ‘K’ of terminal X7 and the other to the
‘COM’. The keypad will function in single channel mode.
18