23
GB
12. Troubleshooting
Fault
Possible cause
Remedy
The compressor
does not start.
• No supply voltage.
• Insufficient supply voltage.
• Outside temperature is too low.
• Motor is overheated.
• Check the supply voltage, the power
plug and the socket-outlet.
• Make sure that the extension cable is
not too long. Use an extension cable
with large enough wires.
• Never operate with an outside tem-
perature of below +5° C.
• Allow the motor to cool down. If
necessary, remedy the cause of the
overheating.
The compressor
starts but there is
no pressure.
• The non-return valve leaks.
• The seals are damaged.
• The drain plug for condensation
water (1) leaks.
• Have a service center replace the
non-return valve.
• Check the seals and have any dam-
aged seals replaced by a service
center.
• Tighten the screw by hand. Check
the seal on the screw and replace if
necessary.
The compressor
starts, pressure
is shown on the
pressure gauge,
but the tools do
not start.
• The hose connections have a
leak.
• A quick-lock coupling has a leak.
• Insufficient pressure set on the
pressure regulator (7).
• Check the compressed air hose and
tools and replace if necessary.
• Check the quick-lock coupling and
replace if necessary.
• Increase the set pressure with the
pressure regulator.