background image

7

6

INTRODUCTION

INTRODUCTION

LCD display signal

SYMBOL

DESCRIPTION

Systolic blood pressure

High blood pressure 

Diastolic blood pressure Low blood pressure 

EXPLANATION

Memory

mmHg

kPa

Measurement Unit of the blood pressure

Measurement Unit of the blood pressure

Low battery

Batteries are low and need to be replaced

Current Time

Year/Month/Day, Hour/Minute

Pulse in beats per minute

Pulse display

Deflation symbol

The cuff is deflating.

Indicate it is in the memory mode and 

which group of memory it is.

Blood pressure monitor is detecting an 

irregular heartbeat during measurement.

Irregular heartbeat

Blood pressure 

level indicator

Indicate the blood pressure level

CAUTION

* Do not wash the cuff in a washing machine or dishwasher!

* The service life of the cuff may vary by the frequency of washing, skin condition, and 

storage state. The typical service life is 10000 times.

* It is recommended that the performance should be checked every 2 years and after 

maintenance and repair, by retesting at least the requirements in limits of the error of the 

cuff pressure indication and air leakage (testing at least at 50mmHg and 200mmHg).

* Please dispose of ACCESSORIES, detachable parts, and the ME EQUIPMENT 

according to the local guidelines.

* Manufacturer will make available on request circuit diagrams, component part lists, 

descriptions, calibration instructions,etc., to assist to service personnel in parts repair.

* The plug/adapter plug pins insulates the device from the main supply. Do not position the 

device in a position where it is difficult to disconnect from the supply mains to safely 

terminate operation of ME equipment.

* The operator shall not touch output of batteries /adapter and the patient simultaneously.

* Cleaning :Dust environment may affect the performance of the unit. Please use the soft 

cloth to clean the whole unit before and after use. Don’t use any abrasive or volatile 

cleaners.

* The device doesn’t need to be calibrated within two years of reliable service.

* If you have any problems with this device, such as setting up, maintaining or using, 

please contact the SERVICE PERSONNEL of Zewa. Don’t open or repair the device by 

yourself in the event of malfunctions. The device must only be serviced, repaired and 

opened by individuals at authorized sales/service centers.

* Please report to Zewa if any unexpected operation or events occur.

* Keep the unit out of reach of infants, young children or pets to avoid inhalation or 

swallowing of small parts. It is dangerous or even fatal.

* Be careful to strangulation due to cables and hoses, particularly due to excessive length.

* At least 30 min required for ME equipment to warm from the minimum storage 

temperature between uses until it is ready for intended use. At least 30 min required for 

ME equipment to cool from the maximum storage temperature between uses until it is 

ready for intended use.

* This equipment needs to be installed and put into service in accordance with the 

information provided in the ACCOMPANYING DOCUMENTS;

* Wireless communications equipment such as wireless home network devices, mobile 

phones, cordless telephones and their base stations, walkie-talkies can affect this 

equipment and should be kept at least a distance d away from the equipment. The 

distance d is calculated by the MANUFACTURER from the 80MHz to 5.8 GHz column of 

Table 4 and Table 9 of IEC 60601-1-2:2014, as appropriate.

* Please use ACCESSORIES and detachable partes specified/ authorised by 

MANUFACTURE. Otherwise, it may cause damage to the unit or danger to the 

user/patients.

* There is no luer lock connectors are used in the construction of tubing, there is a 

possibility that they might be inadvertently connected to intravascular fluid systems, 

allowing air to be pumped into a blood vessel.

* Please use the device under the environment which was provided in the user manual. 

Otherwise, the performance and lifetime of the device will be impacted and reduced.

Heartbeat

Blood pressure monitor is detecting a

heartbeat during measurement.

User 1/User 2

Start measurement for User 1/User 2

Содержание UAM-710

Страница 1: ...user manual carefully and thoroughtly so as to ensure the safe usage of this product and keep the manual well for further reference in case you have problems Manufactured for Zewa Inc 12960 Commerce L...

Страница 2: ...AGEMENT 15 Recall the Records Delete the Records INFORMATION FOR USER 17 Tips for measurement Maintenances ABOUT BLOOD PRESSURE 19 What are systolic pressure and diastolic pressure What is the standar...

Страница 3: ...is intended for adult indoor use only 1 The device is not suitable for use on pregnant women 2 The device is not suitable for use on patients with implanted electrical devices such as cardiac pacemake...

Страница 4: ...to an ecchymosis Please check that operation of the device does not result in prolonged impairment of patient blood circulation When measurement please avoid compression or restriction of the connect...

Страница 5: ...ed to be calibrated within two years of reliable service If you have any problems with this device such as setting up maintaining or using please contact the SERVICE PERSONNEL of Zewa Don t open or re...

Страница 6: ...y 1 Battery powered mode 6VDC 4 AAA batteries 2 AC adaptor powered mode Not included 6V 1A Please only use the recommended AC adaptor model Please unplug the adaptor to depart from the using utility p...

Страница 7: ...ing Or when the monitor is off press SET button shortly it will display the time Then hold pressing SET button to enter the mode for year setting 2 Press the MEM to change the YEAR Each press will inc...

Страница 8: ...t the cuff is at the same level as your heart Turn your palm upwards Sit upright in a chair and take 5 6 deep breaths Rest for 5 minutes before first measuring Wait at least 3 minutes between measurem...

Страница 9: ...st three records If the records are less than three groups it will display the latest record first 2 Press the MEM or SET to get the record you want The most recent record 1 is shown first Each new me...

Страница 10: ...a coffee smoking When talking or moving your fingers When you want to discharge urine To delete records follow these steps Delete Records When the monitor is in the memory recall mode hold pressing ME...

Страница 11: ...5 or there are four or more pulse intervals the difference between each interval and the average is more than the average value of 15 the irregular heartbeat symbol appears on the display when the mea...

Страница 12: ...tion includes a list of error messages and frequently asked questions for problems you may encounter with your blood pressure monitor If the products not operating as you think it should check here be...

Страница 13: ...white backlight V A 60mm 40 5mm Approx 110mm 110mm 41mm 4xAAA batteries user manual warranty book A01 About 22cm 42cm Type BF applied part WARNING No modification of this equipment is allowed Power su...

Страница 14: ...ogical evaluation of medical devices Part 5 Tests for in vitro cytotoxicity ISO 10993 10 2010 Biological evaluation of medical devices Part 10 Tests for irritation and skin sensitization EN ISO 15223...

Страница 15: ...at 1kHz 150 kHz to 80 MHz 3 Vrms 6Vrms in ISM and amateur radio bands 80 Am at 1kHz Electromagnetic environment guidance NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These gu...

Страница 16: ...r the user of the device should assure that it is used in such an environment NOTE If necessary to achieve the IMMUNITY TEST LEVEL the distance between the transmitting antenna and the ME EQUIPMENT or...

Отзывы: