Zeversolar Zeverlution 1000S Скачать руководство пользователя страница 1

Содержание Zeverlution 1000S

Страница 1: ......

Страница 2: ...bols on the label 10 2 5 Basic safety protection 11 3 Unpacking 12 3 1 Scope of delivery 12 3 2 Checking for transport damage 12 4 Mounting 13 4 1 Ambient conditions 13 4 2 Selecting the mounting loca...

Страница 3: ...ctors 31 5 5 4 Connecting the PV array 32 6 Communication 33 6 1 System monitoring via RS485 33 6 2 System monitoring via Ethernet 37 6 3 System monitoring via WiFi 38 6 4 Inverter demand response mod...

Страница 4: ...54 10 Technical Data 56 10 1 DC input data 56 10 2 AC output data 57 10 3 General data 58 10 4 Safety regulations 59 10 5 Efficiency 61 10 6 Power reduction 65 10 7 Tools and torque 67 11 Troubleshoo...

Страница 5: ...aintenance of the following Zeversolar inverters Zeverlution 1000S Zeverlution 1500S Zeverlution 2000S Zeverlution 3000S Observe all documentation that accompanies the inverter Keep them in a convenie...

Страница 6: ...installation and operation of the inverter NOTICE indicates a situation which if not avoided can result in property damage CAUTION indicates a hazardous situation which if not avoided can result in mi...

Страница 7: ...ing capacitance does not exceed 1 0 F 5 When the PV modules are exposed to sunlight a DC voltage is supplied to this equipment 6 When designing the PV system ensure that the values comply with the per...

Страница 8: ...not touch non insulated cable ends Do not touch the DC conductors Do not touch any live components of the inverter Have the inverter mounted installed and commissioned only by qualified persons with t...

Страница 9: ...trings Possible damage to health as a result of the effects of electromagnetic radiation Please maintain a distance of at least 20cm from the inverter when it is in operation Risk of injury due to hot...

Страница 10: ...onent Damage to the seal of the cover in sub zero conditions If you open the cover in sub zero condition the sealing of the cover can be damaged This can lead moisture entering the inverter Do not ope...

Страница 11: ...complies with the requirements of the applicable EC guidelines Certified safety Product is TUV tested and complies with the requirements of the German Equipment and Product Safety Act RCM Mark The pro...

Страница 12: ...ction We provide the following safety protection 1 Over voltage under voltage protection 2 Over frequency under frequency protection 3 Over temperature monitoring 4 Residual current monitoring 5 Insul...

Страница 13: ...air E Documentation 1 set F WiFi antenna 1 piece optional G Smart meter Connector 1 piece optional One spare part for cover mounting A B C D E F G Carefully check all of the components in the carton I...

Страница 14: ...ter in areas where it cannot be touched inadvertently 3 Ensure good access to the inverter for installation and possible service 4 To make sure that heat can dissipate observe the following minimum cl...

Страница 15: ...he inverter to direct sunlight rain and snow to ensure optimal operation and extend service life 8 The mounting method location and surface must be suitable for the inverter s weight and dimensions 9...

Страница 16: ...mount the inverter horizontally 4 Mount the inverter at eye level to make it easy to operate and to read the display 5 The electrical connection area must point downwards Danger to life due to fire or...

Страница 17: ...teady to avoid tilted holes 2 After drilling holes in the wall place two screw anchors into the holes then attach the wall mounting bracket to the wall using the self tapping screws and washers delive...

Страница 18: ...t it is securely in place 5 Push the inverter as far as possible and attach it to both sides of the wall bracket using the M5 screws If a second protective conductor is required in installation site g...

Страница 19: ...live components of the inverter Touching the DC conductors or the live components can lead to lethal electric shocks If you disconnect the DC connectors from the inverter under load an electric arc m...

Страница 20: ...e able to safely disconnect the open circuit voltage of the PV array plus a safety reserve of 20 Install a DC switch to each PV string to isolate the DC side of the inverter We recommend the following...

Страница 21: ...ction area Object Description A DC SWITCH optional switch on or off for PV load B DC input plug in connector to connect the strings C COM connect the monitoring device with network cable D ANT optiona...

Страница 22: ...ed conductors approx 12 mm D Stripping length of the outer sheath of AC cable approx 70 mm Larger cross sections should be used for longer cables Cable design The conductor cross section should be dim...

Страница 23: ...etc 5 4 2 Grid connection Damage to the seal of the cover in sub zero conditions If you open the cover in sub zero condition the sealing of the cover can be damaged This can lead moisture entering th...

Страница 24: ...re than PE 4 Route the AC cable into the inverter through the M20 cable gland 5 If necessary slightly loosen the swivel nut of the cable gland 6 Insert bared conductor into the cord end terminal and c...

Страница 25: ...the screw terminal with N sign and tighten the screw Insert the L conductor brown or black into the screw terminal with L sign and tighten the screw 8 Make sure the insulated conductors are securely c...

Страница 26: ...ounding conductor into the terminal lug and crimp the contact 2 Align the plain washer the terminal lug with the grounding conductor and the ground washer on the screw The teeth of the ground washer m...

Страница 27: ...tects the current difference between the neutral conductor and the line conductor If the current difference increases suddenly the inverter disconnects from the grid The function of the all pole sensi...

Страница 28: ...uit breakers with load switch functionality for load switching The selection of the circuit breaker rating depends on the wiring design wire cross section area cable type wiring method ambient tempera...

Страница 29: ...n the scope of delivery The positive connection cables of the PV modules must be equipped with the positive DC connectors The negative connection cables of the PV modules must be equipped with the neg...

Страница 30: ...on 2 5 mm to 6 mm Number of conductors at least 7 Nominal voltage at least 600V Proceed as follows to assemble each DC connector 1 Strip 12 mm off the cable insulation 2 Route the stripped cable all t...

Страница 31: ...the chamber of the clamping bracket the cable is correctly positioned Proceed to step 5 If the stranded wires are not visible in the chamber the cable is not correctly positioned Release the clamping...

Страница 32: ...the DC connector apart 4 Release the clamping bracket To do so insert a flat blade screwdriver blade width 3 5 mm into the clamping bracket and lever it open 5 Remove the cable Danger to life due to...

Страница 33: ...that the open circuit voltage of the PV array does not exceed the maximum DC input voltage of the inverter 6 Connect the assembled DC connectors to the inverter until they audibly snap into place 7 En...

Страница 34: ...length of the network cable should not exceed 1 000 m The monitoring system layout for inverters is as follows The ZeverCom ZeverManager connects to the inverter via the RJ45 interface and it connects...

Страница 35: ...verter due to moisture and dust penetration If the cable gland are not mounted properly the inverter can be destroyed due to moisture and dust penetration All the warranty claim will be invalid Make s...

Страница 36: ...e the filler plug from the cable gland and keep it well If there is only one network cable please keep a filler plug in the remaining hole of the sealing ring against water ingress 3 Current pin assig...

Страница 37: ...ger or another communication device via the above mentioned network cable 6 Press the sealing ring with the network cable into the cable gland and then tighten the swivel nut firmly torque 2 5 3 0Nm M...

Страница 38: ...rk cable please refer to the relative instruction at section 6 1 The inverter obtains an IP address from the router via DHCP automatically and shows it on the display The time it takes to connect to t...

Страница 39: ...unting the antenna Take the antenna included in the scope of delivery Tighten the antenna into the WIFI connection port by hand Make sure the antenna is securely connected 1 Open your mobile device or...

Страница 40: ...ge www zeversolar com 6 This page shows the WiFi SSID and password information you can change the SSID and WiFi password accordingly default password is zeversolar To ensure highest security of your s...

Страница 41: ...re than 60 reactive power DRM 4 Increase power consumption subject to constraints from other active DRMs DRM 5 Do not generate power DRM 6 Do not generate at more than 50 of rated power DRM 7 Do not g...

Страница 42: ...et on the upper circuit board ComBox 4 Connect the inverter to DRED via the above mentioned network cable 5 Press the sealing ring with the network cable into the cable gland and then tighten the swiv...

Страница 43: ...bol A and B When doing so ensure the conductors are plugged completely into the terminal up to the insulation 3 Route the cable into inverter through the cable gland referring to the network cable con...

Страница 44: ...lution inverters can communicate with Solarlog or Meteocontrol in other words you can use Solarlog or Meteocontrol to monitor Zeverlution inverters For more information please refer to their user manu...

Страница 45: ...rol button and display messages and the language and safety regulation settings 7 1 Overview of the control panel The inverter is equipped with a text display three LEDs indicators and a control butto...

Страница 46: ...line display ComBox IP addr it will show 0 0 0 0 without Combox and bottom display state that connect ZeverCloud or not Line 1 State information E today Daily energy E total Energy generated since th...

Страница 47: ...ected information until you press the button again or the operating state of the inverter changes To save power the backlight of the display turns off automatically after 10s Press the button again to...

Страница 48: ...voltage and frequency are normal Reconnect The inverter is checking feed in conditions after the last fault has been solved Normal Normal The inverter is feeding energy into grid normally fault 1 SCI...

Страница 49: ...nsulation inside the inverter has failed 40 Over Temp The internal temperature exceeds the permitted value 41 Vac differs for M S A different value of grid voltage has been detected by the master and...

Страница 50: ...German Press the button for approx 5s at the entry of Set Language to enter the language menu and select the language The display will switch to current state information automatically and the languag...

Страница 51: ...scroll through the different safety regulations showing on the screen will constantly change For example if you choose the safety regulation for the Netherlands press the control key until the LCD di...

Страница 52: ...ed DC voltage Check the polarity of the DC voltage make sure the DC voltage has the correct polarity Check the PV array s insulation to ground with a multimeter make sure that the insulation resistanc...

Страница 53: ...echanical checks to ensure the inverter is waterproof Make sure the inverter has been correctly mounted with wall bracket Make sure the cover has been correctly mounted Make sure the communication and...

Страница 54: ...age the inverter is waiting for sufficient DC input voltage and cannot feed power into the grid Checking When the initial voltage of the strings exceeds the start up DC input voltage the inverter will...

Страница 55: ...ent is present in the DC cables 4 Release and remove all DC connectors Insert a flat blade screwdriver or an angled screwdriver blade width 3 5 mm into one of the slide slots and pull the DC connector...

Страница 56: ...Unscrew the screws of the screw terminal blocks and the swivel nut of the M20 cable gland remove the AC cable 9 Secure the cover torque 2 2 2 5 Nm using a screwdriver T25 Damage to the inverter due t...

Страница 57: ...rlution 1500S Zeverlution 2000S Zeverlution 3000S DC convertible power cos 1 1150W 1750W 2350W 3150W Max input voltage 500V 600V MPP voltage range 70 450V 70 520V Rated input voltage 360V Min start vo...

Страница 58: ...000 VA Nominal AC voltage range 220V 230V 240V 180V 280V AC power frequency range 50 60 5Hz Rated power frequency rated grid voltage 50Hz 230V Max output current 5 5A 7 5A 10A 15A Power factor rated p...

Страница 59: ...Noise emission typical 15 dB A 1m Installation indoor outdoor Mounting information wall mounting bracket DC connection technology SUNCLIX AC connection technology screw clamp terminal Operating tempe...

Страница 60: ...apability Residual current monitoring GFCI function Earth Fault Alarm cloud based audible and visible AU Protection class according to IEC 62103 overvoltage category according to IEC 60664 1 I II DC I...

Страница 61: ...egrated NS protection can be changed with a password The displacement factor cos phi value is not necessary to be adjustable if the power generation system SAmax 3 68KVA and was set to 1 as default in...

Страница 62: ...graphically In all cases the efficiency refers to the standardized power output Pac Pac r according to EN 50524 VDE 0126 13 2008 10 cl 4 5 3 Notes Values are based on rated grid voltage cos phi 1 and...

Страница 63: ...62 Installation and Operating Instructions V03 Efficiency curve Zeverlution 1500S Efficiency Max efficiency European weighted efficiency 97 1 96 4 MPPT efficiency 99 50...

Страница 64: ...Installation and Operating Instructions V03 63 Efficiency curve Zeverlution 2000S Efficiency Max efficiency European weighted efficiency 97 2 96 6 MPPT efficiency 99 50...

Страница 65: ...64 Installation and Operating Instructions V03 Efficiency curve Zeverlution 3000S Efficiency Max efficiency European weighted efficiency 97 4 97 MPPT efficiency 99 50...

Страница 66: ...rameters including ambient temperature and input voltage grid voltage grid frequency and power available from the PV modules This device can decrease power output during certain periods of the day acc...

Страница 67: ...duction with increased ambient temperature Zeverlution 2000S Power reduction with increased ambient temperature Zeverlution 3000S The power reduction curve is tested at normal air pressure Different a...

Страница 68: ...t Socket wrench Open end of 30 Swivel nut of M25 cable gland Hand tight Open end of 24 Swivel nut of M20 cable gland Hand tight Open end of 15 Swivel nut of sunclix connector 2 0Nm Open end of 10 Hex...

Страница 69: ...e service 33 Check the grid frequency and observe how often major fluctuations occur If this fault is caused by frequent fluctuations try to modify the operating parameters after informing the grid op...

Страница 70: ...therwise make a visual inspection of all PV cables and modules Make sure the grounding connection of the inverter is reliable If this fault occurs often contact the service 40 Check whether the airflo...

Страница 71: ...switch annually Perform cleaning by cycling the switch to 1 and 0 positions 5 times The DC switch is located at the lower left of the enclosure 12 2 Cleaning the heat sink Clean the heat sink with com...

Страница 72: ...ot dispose the Zeverlution inverter with normal domestic waste 14 Warranty The factory warranty card is enclosed with the package please keep well the factory warranty card Warranty terms and conditio...

Страница 73: ...you with the necessary assistance Inverter device type Inverter serial number Type and number of connected PV modules Error code Mounting location Installation date Warranty card Jiangsu Zeversolar Ne...

Страница 74: ......