32 Installation and Operating Instructions V01
6.2 System monitoring via Ethernet
User can monitor the inverter through the integrated Ethernet module (optional),
The connection diagram between the inverter and internet with
network cable is
shown as follows.
Internet
LAN
Inverter_1
Inverter_n
Router
Internet
Solarcloud
LAN
LAN
Inverter_2
For network cable connection between the router and the Ethernet port on the
Ethernet module, please refer to the relative instruction at section 6.1.
The inverter obtains an IP address from the router via DHCP automatically and
shows it on the display. It takes time to connect to the network depending on the
network communication conditions.
Possible reason of communication failure due to DHCP
The router needs to support DHCP services if the Ethernet module uses the DHCP function.
Possible reason of communication failure due to closed port
Port #6655
~
#6660 is used to transfer data to Zevercloud. These ports must be opened,
or else the Ethernet module cannot communicate with the Zevercloud and upload data.