Installation and Operating Instructions V01
25
5.5.3 Disassembling the DC connectors
1.
Set the DC-Switch of the inverter to position “
o”
.
2.
Unscrew the swivel nut.
3.
To release the DC connector, insert a flat-blade screwdriver (blade width: 3.5
mm) into the side catch mechanism and lever open.
4.
Carefully pull the DC connector apart.
5.
Release the clamping bracket. To do so, insert a flat-blade screwdriver (blade
width: 3.5 mm) into the clamping bracket and lever it open.
6.
Remove the cable.
Danger to life due to high voltages on DC conductors
When exposed to sunlight, the PV array generates dangerous DC voltage which is present in
the DC conductors. Touching the DC conductors can lead to lethal electric shocks.
• Cover the PV modules.
• Do not touch the DC conductors.