ELECTRICAL INSTALLATION
E605
ALTERNATOR
It is accessible after hinging the bonnet
away. Charging check is indicated by a
red control on the compound dashboard
device, which must go out after starting.
When repairing tractor by electric
welding, all the conductors must
be disconnected alternator. Pro-
tect conductor "+B" against short
circuit.
ALTERNATOR MAINTENANCE
When washing and cleaning tractor protect alternator prior to penetration of
water or oil!
You must not disconnect alternator from accumulator during operation!
Alternator must not ever be put in operation with a disconnected conductor
from of clamp “+B” and connected clamp “+D“. Such condition when increas-
ing the revolutions may cause an exceptionally high alternator voltage which
would damage semiconductors!
Never short circuit any clamp of alternator in operation!
Alternator must not be over activated. There is a risk of semiconductors dam-
age with this intervention!
Mind the perfect electrical joint on connecting clamps and on perfect alterna-
tor grounding!
Alternator must not be overpoled not even for a short time!