Machined area record
PHS18N012
Enter the aggregation settings menu.
Make sure you have the correct user and the aggregate width (1) preset or set the user and the width of the
aggregation. Each user has their own processed area values recorded; when a user changes, the processed
area on the primary screen displays values valid for the selected user.
By pressing the (
C
) and (
D
) buttons select the item (2) and press the (
B
) key to start the recording of the
processed area (the item is marked with a check mark).
From now on, when the tractor is in motion, the area being processed will be recorded, depending on the
aggregate width and the distance traveled.
The processed area is only recorded when the arms of the rear three-point hitch are lowered in
the working position or when the front or rear PTO is switched on or the conditions are met together.
The recording of the processed area ends when you select the item (
3
) and (
B
) by pressing the (
C
) and
(
D
) buttons in the menu of the processed area and exit the recording of the processed area (marked with
a check mark).
If you re-start the recording of the processed area, the newly read values are added to the already stored
values.
If you need to change a user during the recording of the workspace, close the record of the workspace,
select another user and the width of the aggregate, start the recording of the processed area again, the
newly read values are added to the already stored values for the newly selected user.
To reset the processed area values for the selected user, use (
C
) and (
D
) buttons to select the item (4)
and press button (
B
) to reset the values.
To reset the processed area for all users, use (
C
) and (
D
) buttons to select the item (5) and press button
(
B
) to reset the values.
When you return to the main screen, there will be no value for the processed area display field
The reset values can not be restored in any way.
System of treatment of exhaust gases - setting
The regeneration of the diesel particulate filter in case of increased temperature of exhaust gases is
performed at higher engine load. The system of regeneration of the diesel particulate filter DPF can be
controlled through the menu of the engine setting on the instrument panel. The regeneration can be
controlled in two modes. The mode of automatic regeneration of the diesel particulate filter and inhibition of
regeneration of the DPF filter (for safety reasons only).
Note:
Setting of individual modes is described in Chapter System of Treatment of Exhaust Gases.
INSTRUMENT PANEL
72
Содержание CRYSTAL HD 150
Страница 1: ...CRYSTAL HD 150 170 Tractor is Zetor Since 1946 OPERATOR S MANUAL 2 2018 150 170 2 2018 2 2018...
Страница 3: ...2...
Страница 25: ...NOTES 24...
Страница 31: ...NOTES 30...
Страница 81: ...NOTES 80...
Страница 125: ...NOTES 124...
Страница 131: ...NOTES 130...
Страница 169: ...NOTES 168...
Страница 183: ...Fuse panel B C18N004 ELECTRIC INSTALLATION 182...
Страница 227: ...226...
Страница 232: ...231...
Страница 234: ...www zetor com zetor zetor com Made in EU...