background image

Zesto Audio 2015  

 

P a g e  

 

8. 

VENTILATION: 

Slots and openings in the enclosure create ventilation to protect the component from overheating. All of 

these openings must remain unobstructed. Allow at least 12 inches of clearance above the unit, 1 inch below and an 
opening behind the unit for airflow. Do not place the unit on a bed, sofa, rug, built-in bookcase, or rack without 
adequate ventilation. 

  
9. 

GROUNDING OR POLARIZATION: 

As a safety feature, the unit may be equipped with a polarized alternating current 

line plug in which one blade is wider than the other and a has an additional grounding blade. This plug will fit into the 
power outlet only one way. If you cannot insert the plug fully into the outlet, try reversing the plug. If the plug still will 
not fit, contact a licensed electrician to update your outlet. Do not defeat the safety purpose of the polarized plug. 

  
10. 

POWER SOURCES: 

Operate the unit only from the power source indicated on the marking label on the back of the 

unit. If you are unsure of the type of power supplied to your home, consult your unit dealer or local power company. 

  
11. 

POWER CORD PROTECTION: 

Arrange power supply cords so that they do not suffer from foot traffic or pinching by 

items placed on or against them. Pay close attention to cords where plugs enter the AC outlet and where they exit 
from the unit. 

  
12. 

LIGHTNING: 

For added protection during a lightning storm or when the component is idle for long periods of time, 

unplug the unit from the wall outlet. This will help protect the unit from lightning and power line surge damage. 

  

13. 

POWER LINES: 

Do not locate an outside antenna system in the vicinity of overhead power lines or other electric light 

or power circuits. When installing an outside antenna system, take extreme care to avoid touching the power lines or 
circuits; contact with them could be fatal. 

  

14. 

OVERLOADING: 

Do not overload wall outlets, extension cords, or integral convenience receptacles as this increases 

the risk of fire or electric shock. 

  
15. 

REPLACEMENT PARTS: 

When replacement parts are required, be sure the service technician has used 

replacement parts specified by the manufacturer or those having the same characteristics as the original parts. 
Unauthorized substitutions may result in fire, electric shock or other hazards. 

  
16. 

SAFETY CHECK: 

Upon completion of any service or repairs to the unit, ask the service technician to perform safety 

checks to ensure the unit is in proper operating condition. 

  
17. 

IMPORTANT SAFETY NOTE: 

 

• Before connecting a new product such as the EROS 300 to your audio or home theater system, turn off all other 

equipment (preferably unplugging them from the AC power source). Many audio components feature automatic 
turn-on circuits that may activate during an installation, potentially causing damage to electronic components or 
speakers. This type of damage is not covered by product warranties, and Zesto Audio specifically disclaims 
responsibility for any such damage.  

• 

Power Cord: 

The removable IEC power cord provided with your unit was specifically designed for use with this 

product, but other AC cords may be used. Consult your dealer for advice on AC power cords and high quality wire 
in your system.  

• 

AC Fuse: 

The fuse is located inside the IEC power entry connector and is user replaceable. Only replace fuse with 

the exact same type that was removed. Only use slow blow fuse. If the unit does not power up, contact an 
authorized service representative.  

• 

Wiring: 

Cables running inside walls should have the appropriate markings to indicate compliance and listing by the 

UL, CSA or other standards required by the UL, CSA, NEC, or your local building code. Questions about cables 
inside of walls should be directed to a qualified custom installer, licensed electrician, or low-voltage contractor. 

  

 

Содержание EROS 300

Страница 1: ...er Amplifier Owner s Manual Please read carefully before installing and operating this equipment Zesto Audio 3138 Calle Estepa Thousand Oaks California 91360 805 807 1840 www zestoaudio com george zes...

Страница 2: ...ience for you I am proud to put my name on it and honored to share this with you Wishing you many happy years of listening Sincerely George Counnas President of Zesto Audio FYI Zesto is Greek for hot...

Страница 3: ...ot place the unit on an unstable cart stand tripod bracket or table The unit may fall causing injury to a person or damage to the unit Mount the unit according to the manufacturer s instructions with...

Страница 4: ...power lines or circuits contact with them could be fatal 14 OVERLOADING Do not overload wall outlets extension cords or integral convenience receptacles as this increases the risk of fire or electric...

Страница 5: ...adiate radio frequency energy and if not installed and used in accordance with the instructions it may cause harmful interference to radio communications However there is no guarantee that interferenc...

Страница 6: ...slow blow fuse Fuse installed in mains inlet connector Optional factory installed 220V 230V 240V mains with 3 15 Amp slow blow fuse Input RCA Single Ended SE High quality recessed gold pin connectors...

Страница 7: ...to reach rated output Detailed Specs Monaural Auto bias No negative feedback Frequency response 20Hz to 50Khz 2dB Total Harmonic Distortion 0 8 at 1W into 8 Ohms Gain of 29dB Noise level 5 mV RMS into...

Страница 8: ...that could damage your speakers or other equipment It is customary for vacuum tube equipment when it is first turned on while the unit is powering up to have a brief initial hum coming from the unit...

Страница 9: ...binding posts You can also connect the speaker cable using a 4 pin SpeakOn connector SpeakOn Wiring Diagram 4 1 1 8 2 2 Input Using RCA or XLR interconnect cables connect your preamp to the input of t...

Страница 10: ...rd fuse Warning The EROS is designed for Slow Blow fuses If you install a standard fuse it is likely to blow when you turn the amp on For 120 Volt mains we use a 6 3 Amp Slow blow fuse Not a 5 Amp Slo...

Страница 11: ...been misused abused damaged by accident or neglect or in transport once in possession of purchaser The warranty is also void if the product has been tampered with or has been repaired or modified by a...