Tips and Tricks 

A few things to know about tube power amps 

 

When the amp is first turned on there is a brief inrush of power (your lights may dim for an instant). After that, the 
amp draws a lot less power. 

 

The best Audiophile accessory to buy for a power amp is good clean dedicated mains power with a proper ground 
to your system

 

 

Safety Tips 

 

Power amps get hot when operating properly. It’s important to provide adequate ventilation of at least 12” above 
the unit and on all sides. 

 

Turn unit OFF when changing cables. 

 

If you break a tube, turn unit off immediately. Wait at least 1 hour for the high voltage to discharge completely to 
replace it. 

 

If you spill any liquids on the unit, turn off immediately and call the factory. 

 

Fuses:

 

 

There are many safety features built into a Zesto power amp. The purpose of a fuse is to protect the amplifier, 
sometimes they wear out and sometimes the fuse will blow. The mains fuse is the most likely fuse to blow .It is 
located in the IEC power inlet connector. All fuse types are not created equal. For example, a Slow Blow fuse is 
not the same as a Standard fuse.  

 

Warning!

 The EROS 

is designed for “Slow Blow” fuses. If you install a standard fuse, it is likely to blow when you 

turn the amp on. 

 

For 120 Volt mains we use a 6.3 Amp Slow blow fuse. (Not a 5 Amp Slow Blow) 

 

For 220, 230, 240 Volt mains we use a 3.15 Amp Slow blow fuse. 

 

Generally if a fuse blows you need to replace it with the same fuse. If it blows again contact your dealer 

 

More Safety 

 

Caution: 

Tube electronics should not be turned ON, then OFF, then ON again quickly. This could blow a fuse. 

Once the unit is ON, it is safe to wait a minute (60 seconds) before switching OFF, then another 60 seconds 
before you can turn it back on. If you blow a fuse replace with the same slow blow fuse. 

 

Power amps output tubes (KT88) get very hot when operating properly; tubes can exceed 300 degrees 
Fahrenheit. 

 

Never

 move an amplifier with hot tubes. Tubes are the most vulnerable when they are hot and it will break the 

filament not the glass. 

 

It’s important to provide adequate ventilation of at least 12” above the unit and on all sides. 

 

To protect your speakers, turn the power amp OFF when changing any cables in your system. 

 

If you break a tube, turn unit off immediately. Wait at least 1 hour for the high voltage to discharge completely to 
replace it. 

 

If you spill any liquids on the unit, turn off immediately and call the factory. 

Содержание EROS 300

Страница 1: ...er Amplifier Owner s Manual Please read carefully before installing and operating this equipment Zesto Audio 3138 Calle Estepa Thousand Oaks California 91360 805 807 1840 www zestoaudio com george zes...

Страница 2: ...ience for you I am proud to put my name on it and honored to share this with you Wishing you many happy years of listening Sincerely George Counnas President of Zesto Audio FYI Zesto is Greek for hot...

Страница 3: ...ot place the unit on an unstable cart stand tripod bracket or table The unit may fall causing injury to a person or damage to the unit Mount the unit according to the manufacturer s instructions with...

Страница 4: ...power lines or circuits contact with them could be fatal 14 OVERLOADING Do not overload wall outlets extension cords or integral convenience receptacles as this increases the risk of fire or electric...

Страница 5: ...adiate radio frequency energy and if not installed and used in accordance with the instructions it may cause harmful interference to radio communications However there is no guarantee that interferenc...

Страница 6: ...slow blow fuse Fuse installed in mains inlet connector Optional factory installed 220V 230V 240V mains with 3 15 Amp slow blow fuse Input RCA Single Ended SE High quality recessed gold pin connectors...

Страница 7: ...to reach rated output Detailed Specs Monaural Auto bias No negative feedback Frequency response 20Hz to 50Khz 2dB Total Harmonic Distortion 0 8 at 1W into 8 Ohms Gain of 29dB Noise level 5 mV RMS into...

Страница 8: ...that could damage your speakers or other equipment It is customary for vacuum tube equipment when it is first turned on while the unit is powering up to have a brief initial hum coming from the unit...

Страница 9: ...binding posts You can also connect the speaker cable using a 4 pin SpeakOn connector SpeakOn Wiring Diagram 4 1 1 8 2 2 Input Using RCA or XLR interconnect cables connect your preamp to the input of t...

Страница 10: ...rd fuse Warning The EROS is designed for Slow Blow fuses If you install a standard fuse it is likely to blow when you turn the amp on For 120 Volt mains we use a 6 3 Amp Slow blow fuse Not a 5 Amp Slo...

Страница 11: ...been misused abused damaged by accident or neglect or in transport once in possession of purchaser The warranty is also void if the product has been tampered with or has been repaired or modified by a...

Отзывы: